Fabrication of Two-Layer Microfluidic Devices with Porous Electrodes Using Printed Sacrificial Layers.

Micromachines (Basel)

Graduate School of Engineering, Tohoku University, 6-6-11-604 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan.

Published: August 2024

AI Article Synopsis

  • This study introduces a new method for creating two-layer microfluidic devices with porous electrodes, which are valuable for bioanalytical applications, particularly in microphysiological systems.
  • The innovative fabrication process involves 3D printing sacrificial layers using Pluronic F-127 ink, placing a porous gold electrode in between, and then removing the sacrificial layers to create the device structure.
  • The newly developed device was capable of performing electrochemical assays to measure serotonin levels, demonstrating its potential for future use in various biological applications.

Article Abstract

Two-layer microfluidic devices with porous membranes have been widely used in bioapplications such as microphysiological systems (MPS). Porous electrodes, instead of membranes, have recently been incorporated into devices for electrochemical cell analysis. Generally, microfluidic channels are prepared using soft lithography and assembled into two-layer microfluidic devices. In addition to soft lithography, three-dimensional (3D) printing has been widely used for the direct fabrication of microfluidic devices because of its high flexibility. However, this technique has not yet been applied to the fabrication of two-layer microfluidic devices with porous electrodes. This paper proposes a novel fabrication process for this type of device. In brief, Pluronic F-127 ink was three-dimensionally printed in the form of sacrificial layers. A porous Au electrode, fabricated by sputtering Au on track-etched polyethylene terephthalate membranes, was placed between the top and bottom sacrificial layers. After covering with polydimethylsiloxane, the sacrificial layers were removed by flushing with a cold solution. To the best of our knowledge, this is the first report on the sacrificial approach-based fabrication of two-layer microfluidic devices with a porous electrode. Furthermore, the device was used for electrochemical assays of serotonin and could successfully measure concentrations up to 5 µM. In the future, this device can be used for MPS applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11356774PMC
http://dx.doi.org/10.3390/mi15081054DOI Listing

Publication Analysis

Top Keywords

microfluidic devices
24
two-layer microfluidic
20
devices porous
16
sacrificial layers
16
fabrication two-layer
12
porous electrodes
12
soft lithography
8
porous electrode
8
microfluidic
7
devices
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!