The purpose of the present study was to evaluate clinical and functional outcomes, graft integrity rate and progression of osteoarthritis after superior capsular reconstruction (SCR) at short-term follow-up. Consecutive patients that underwent SCR using an acellular dermal xeno- or allograft between May 2018 and June 2020 for the treatment of irreparable posterosuperior rotator cuff tears were included. Shoulder function (American Shoulder and Elbow Surgeons [ASES] score), pain (Visual Analog Scale [VAS] for pain) and active shoulder range of motion (ROM) were evaluated preoperatively and after a minimum of 24 months postoperatively. Isometric strength was measured at follow-up and compared to the contralateral side. Magnetic resonance imaging was performed to evaluate graft integrity and osteoarthritis progression (shoulder osteoarthritis severity [SOAS] score). Twenty-two patients that underwent SCR using a xeno- (n = 9) or allograft (n = 13) were evaluated 33.1 ± 7.2 months postoperatively. Four patients in the xenograft group underwent revision surgery due to pain and range of motion limitations and were excluded from further analysis (revision rate: 18.2%). Shoulder function (ASES score: 41.6 ± 18.8 to 72.9 ± 18.6, < 0.001), pain levels (VAS for pain: 5.8 ± 2.5 to 1.8 ± 2.0, < 0.001) and active flexion ( < 0.001) as well as abduction ROM ( < 0.001) improved significantly from pre- to postoperatively. Active external rotation ROM did not improve significantly ( = 0.924). Isometric flexion ( < 0.001), abduction ( < 0.001) and external rotation strength ( = 0.015) were significantly lower in the operated shoulder compared to the non-operated shoulder. Ten shoulders demonstrated a graft tear at the glenoid (n = 8, 44.4%) or humerus (n = 2, 11.1%). Graft lysis was observed in seven shoulders (38.9%). The graft was intact in one shoulder (5.6%), which was an allograft. A significant progression of shoulder osteoarthritis was observed at follow-up (SOAS score: 42.4 ± 10.1 to 54.6 ± 8.4, < 0.001). At short-term follow-up, SCR using an acellular dermal xeno- or allograft resulted in improved shoulder function and pain with limitations in active external rotation ROM and isometric strength. Graft failure rates were high and osteoarthritis progressed significantly. Retrospective cohort study, Level III.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11355822PMC
http://dx.doi.org/10.3390/jcm13164646DOI Listing

Publication Analysis

Top Keywords

shoulder function
16
acellular dermal
12
xeno- allograft
12
external rotation
12
shoulder
11
superior capsular
8
capsular reconstruction
8
graft failure
8
graft integrity
8
short-term follow-up
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!