Reports suggest possible risks of adverse cardiovascular reactions, including heart failure, associated with non-ergot dopamine agonist (DA) use in Parkinson's disease (PD). The objectives of our review were to evaluate the risk of heart failure and other adverse cardiovascular reactions in PD patients who received a non-ergot DA compared with other anti-PD pharmacological interventions, placebo, or no intervention. Studies were identified via searches of six bibliographic databases. Randomized controlled trials (RCTs) and non-randomized studies (NRS) were eligible for study inclusion. Random-effect meta-analyses were performed to estimate adverse cardiovascular reaction risks. Quality of evidence was assessed using GRADE. In total, forty-four studies (thirty-six RCTs and eight NRS) satisfied our inclusion criteria. A single RCT found no significant difference in the risk of heart failure with ropinirole compared with bromocriptine (odds ratio (OR) 0.39, 95% confidence interval (CI) 0.07 to 2.04; low certainty). Conversely, three case-control studies reported a risk of heart failure with non-ergot DA treatment. The quality of evidence for the risk of heart failure was judged as low or very low. Findings suggest that non-ergot DA use may be associated with adverse cardiovascular outcomes, including heart failure. Studies are needed to better understand cardiovascular risks associated with PD treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11352331PMC
http://dx.doi.org/10.3390/brainsci14080776DOI Listing

Publication Analysis

Top Keywords

heart failure
28
risk heart
20
adverse cardiovascular
20
cardiovascular reactions
12
non-ergot dopamine
8
failure adverse
8
parkinson's disease
8
including heart
8
quality evidence
8
heart
7

Similar Publications

Type 2 diabetes (T2D) frequently coexists with cardiorenal complications. Therefore, a holistic approach to patient management is required, with specialists such as primary care physicians, cardiologists, endocrinologists, and nephrologists working together to provide patient care. Although glycemic control is important in the management of T2D, patients with T2D and acceptable glycemic control are still at risk from cardiovascular (CV) events such as stroke, heart attack, and heart failure (HF).

View Article and Find Full Text PDF

Background: Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys).

Methods: This was a prospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP).

View Article and Find Full Text PDF

Left atrial strain (LAS) was recently introduced as a parameter that reflects on left atrial function. Consequently, changes in LAS can inform the development of cardiovascular diseases, hence providing a window for non-invasive and cost-effective testing of these diseases and their complications at early stages of development, potentially offering a segway towards preventive interventions. LAS has yet to be implemented into standard practice.

View Article and Find Full Text PDF

Background: Little is known about how younger and older hospitalized patients differ with respect to reasons for admission, comorbidities, diagnostics, treatment and intercurrent problems.

Objective: The aim of the study was to compare the previously named characteristics in the clinical profile of patients > 90 years old (nonagenarians) with a control group of patients 70-75 years old admitted to an emergency hospital department for internal medicine and cardiology.

Material And Method: The study included all consecutive nonagenarians and gender-matched control patients who were admitted during 2011.

View Article and Find Full Text PDF

Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.

Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.

Results: The majority of patients (87.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!