Objective: To compare anesthetic parameters using a novel prone single transverse chest roll technique (STR) to the standard thoraco-pelvic dual transverse roll technique (DTR).

Methods: A retrospective review of 441 patients who underwent PCNL between 2018 and 2022 was performed. A total of 4 surgeons were included-surgeon 1 utilized the STR technique while surgeons 2, 3, and 4 used the DTR technique. Anesthetic parameters including end-tidal CO (ETCO), mean arterial pressure (MAP), peak airway pressure (P), plateau airway pressure (P), positive end-expiratory pressure (PEEP), oxygen saturation (SpO), and tidal volume (TV) were compared between both groups at 0 (supine), 15-, 30-, and 60-minute post-intubation intervals. Mixed effects regression models with interaction and pairwise comparisons were made between both groups (P <.05).

Results: A total of 581 PCNLs were performed with 199 using STR and 382 using DTR. Surgery duration, ASA class, and age were similar amongst the STR and DTR groups. Estimated blood loss (59cc vs 83cc, P = .007) and length of stay (77 hrs vs 163 hrs, P = <.001) was significantly lower in the STR group. There was a significantly lower P, P and TV in the STR compared to DTR group at 0, 15, 30, and 60 minutes (P <.001).

Conclusion: Usage of a single transverse chest roll during prone PCNL appears to be a safe positioning method. STR patients had lower P and P at all time points, which has been shown to be predictive of lower blood loss.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.urology.2024.08.037DOI Listing

Publication Analysis

Top Keywords

single transverse
8
transverse chest
8
chest roll
8
anesthetic parameters
8
roll technique
8
airway pressure
8
technique
5
outcomes single
4
roll prone
4
prone positioning
4

Similar Publications

An ultrasensitive angular interrogation metasurface sensor based on the TE mode surface lattice resonance.

Microsyst Nanoeng

January 2025

National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Beijing, 100871, PR China.

The localized surface plasmon resonance metasurface is a research hotspot in the sensing field since it can enhance the light-matter interaction in the nanoscale, but the wavelength sensitivity is far from comparable with that of prism-coupled surface plasmon polariton (SPP). Herein, we propose and demonstrate an ultrasensitive angular interrogation sensor based on the transverse electric mode surface lattice resonance (SLR) mechanism in an all-metal metasurface. In theory, we derive the sensitivity function in detail and emphasize the refraction effect at the air-solution interface, which influences the SLR position and improves the sensitivity performance greatly in the wide-angle.

View Article and Find Full Text PDF

Osteogenesis imperfecta (OI) is a rare genetic disorder affecting mainly type I collagen, which leads to bone fragility and deformities. OI patients also present craniofacial abnormalities such as macrocephaly and malocclusion. Recently, craniofacial dysmorphism was highlighted in the osteogenesis imperfecta mouse (oim), a validated model of the most severe form of OI.

View Article and Find Full Text PDF

Aims: Hypertrophic cardiomyopathy (HCM) is characterized by unexplained left ventricular hypertrophy (LVH) with key pathologic processes including myocardial necrosis, fibrosis, inflammation, and hypertrophy, which are involved in heart failure (HF), stroke, and even sudden death. Our aim was to explore the communication network among various cells in the heart of transverse aortic constriction (TAC) surgery induced HCM mice.

Materials And Methods: Single-cell RNA-seq data of GSE137167 was downloaded from the Gene Expression Omnibus (GEO) database.

View Article and Find Full Text PDF

Background: For many colorectal cancer patients, primary surgery is the standard care of treatment. Further insights in perioperative care are crucial. The aim of this study is to assess the prognostic value of body composition for postoperative complications after laparoscopic and open colorectal surgery.

View Article and Find Full Text PDF

A valid novel ground reaction force distribution algorithm to determine midfoot kinetics of gait with a single force plate.

Gait Posture

December 2024

Marquette University, 1250 W. Wisconsin Ave, Milwaukee, WI 53233, United States; Shriners Children's Chicago, 2211 N. Oak Park Ave, Chicago, IL 60707, United States.

Background: Understanding midfoot joint kinetics is valuable for improved treatment of foot pathologies. Segmental foot kinetics cannot currently be obtained in a standard gait lab without the use of multiple force plates or a pedobarographic plate overlaid with a force plate due to the single ground reaction force (GRF) vector.

Research Question: Can an algorithm be created to distribute the GRF into multiple segmental vectors that will allow for calculation of accurate midfoot and ankle moments?

Methods: 20 pediatric subjects (10 typically developing, 10 with foot pathology) underwent multi-segment foot gait analysis using the Milwaukee Foot Model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?