The air disinfection efficacy of upper-room 222 nm Far-UVC was experimentally investigated in a real-size chamber under well-mixed air conditions. Two bacteria (Escherichia coli, Staphylococcus epidermidis) and two bacteriophages (MS2, and P22) were selected for the test. The study considered different lamp source arrangements, including single and double sources, stationary and rotating operating modes, and an overlapping mode with a 45° irradiation angle. A numerical view-factor model was developed to analyze the irradiance distributions. Four irradiation angles, 30°, 45°, 60°, and 90°, were chosen. The results show that the lamps operating with an irradiation angle of 45° provide the highest chamber-averaged irradiance. This suggests an optimal irradiance level for a given room dimension, as inferred from the view factor model. Experimental results indicated that the overlapping mode with a 45° irradiation angle consistently outperformed both the stationary mode and rotating mode in disinfection. This can be attributed to the higher chamber-averaged irradiance, which is also supported by the numerical model predictions. The increment ratios ranged from 14.9 % to 42.9 % compared to the stationary mode. The susceptibility constants of Escherichia coli, Staphylococcus epidermidis, MS2, and P22 were measured as 0.572 m/J, 0.099 m/J, 0.060 m/J, and 0.081 m/J respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhazmat.2024.135571 | DOI Listing |
Radiol Case Rep
March 2025
Department of Otorhinolaryngology Head and Neck Surgery, Charles Nicolle Hospital, Tunis, Tunisia.
Tracheal adenoid cystic carcinoma is a rare malignancy. We report the case of a 65-year-old male who presented to our department due to a 3-month history of mild dysphagia without other associated symptoms. The neck, laryngeal, and hypopharyngeal examinations were normal.
View Article and Find Full Text PDFPhys Imaging Radiat Oncol
October 2024
Aarhus University Hospital, Danish Centre for Particle Therapy, Aarhus N, Denmark.
Background And Purpose: Radiotherapy for paediatric posterior fossa tumours may cause complications in the brainstem and upper spinal cord due to high doses. With proton therapy (PT) this risk may increase due to higher relative biological effectiveness (RBE) from elevated linear energy transfer (LET). This study assesses variations in LET in the brainstem and spinal cord in proton treatment plans from European centres.
View Article and Find Full Text PDFJ Colloid Interface Sci
January 2025
Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, Nanjing Forestry University, Nanjing 210037 China; College of Chemical Engineering, Jiangsu Key Lab for the Chemistry & Utilization of Agricultural and Forest Biomass, Nanjing Forestry University, Nanjing 210037 China. Electronic address:
Poly(N-isopropylacrylamide) (PNIPAM) composite hydrogels have recently emerged as promising candidates for soft hydrogel actuators. However, developing a facile and fast method to obtain multifunctional PNIPAM hydrogel actuators with simulating biological versatility remains a major challenge. Herein, we developed a fast-redox initiation system to prepare PNIPAM/sodium carboxymethyl cellulose (CMC)/TCT MXene nanocomposite hydrogel with multidirectional actuating behaviors and improved mechanical properties.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Department of Mechanical Engineering, The Pennsylvania State University, University Park, PA 16803, USA.
Traditional defect recovery methods rely on high-temperature annealing, often exceeding 750 °C for FeCrAl. In this study, we introduce electron wind force (EWF)-assisted annealing as an alternative approach to mitigate irradiation-induced defects at significantly lower temperatures. FeCrAl samples irradiated with 5 MeV Zr ions at a dose of 10 cm were annealed using EWF at 250 °C for 60 s.
View Article and Find Full Text PDFMed Dosim
January 2025
Department of Radiation Oncology, University of Rochester Medical Center, Rochester, NY.
Purpose: In radiotherapy treatment planning systems, modelling of superficial dose may be aided by a body contour that is, by default, placed at the outermost air-tissue interface. Here we investigate the accuracy of superficial dose calculated using either the default body contour (DBC) or an extended body contour (EBC) compared to radiochromic film measurements made on a slab phantom and an anthropomorphic phantom.
Methods: Depth dose curves in the superficial region of the slab phantom were measured using stacked radiochromic films and irradiated using static beams delivered from varying incident angles.