Current control approaches for gross prosthetic arm movement mainly regulate movement over a continuous range of target poses. However, these methods suffer from output fluctuation caused by input signal variations during gross arm movements. Prosthesis control approaches with a finite number of discrete target poses can address this issue and reduce the complexity of the pose control process. However, it remains under-explored in the literature and suffers from the consequences of misclassifying the target poses. Here, we propose a novel Uncertainty-Aware Discrete-Target Prosthesis Control (UA-DPC) approach. This approach consists of (1) an uncertainty-aware classification scheme to reduce unintended pose switches caused by misclassifications, and (2) real-time trajectory planning that adjusts motion to be rapid or conservative based on low or high quantified uncertainty, respectively. By addressing the impact of misclassification, this approach facilitates more efficient and smooth movements. Human-in-the-loop experiments were conducted in a virtual reality environment with 12 non-disabled participants. The participants controlled a transhumeral prosthesis using three approaches: the proposed UA-DPC, a discrete-target approach based on a traditional off-the-shelf classifier, and a continuous-target approach. The results demonstrate the superior performance of UA-DPC, which provides more efficient task completion with fewer misclassification instances as well as smoother residual limb and prosthesis movement.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNSRE.2024.3450973DOI Listing

Publication Analysis

Top Keywords

prosthesis control
12
target poses
12
discrete-target prosthesis
8
uncertainty-aware classification
8
gross arm
8
arm movement
8
control approaches
8
control
5
approach
5
control uncertainty-aware
4

Similar Publications

Objectives: Nonsteroidal anti-inflammatory drugs (NSAIDs) are often prescribed following the placement of dental implants, but the effects of these drugs on the osseointegration process are poorly understood. We designed a randomized, placebo-controlled pilot study to quantitatively assess the effect of NSAIDs during early implant osseointegration.

Materials And Methods: Subjects receiving a maxillary dental implant were randomized to take naproxen or placebo for 7 days after the surgery.

View Article and Find Full Text PDF

Comparative Analysis of Gelatin/Polylactic Acid and Commercial PLA Membranes for Guided Bone Regeneration: A Randomized Clinical Trial.

Med Sci Monit

January 2025

Department of Oral Implantology, The Affiliated Stomatology Hospital, Jiangxi Medical College, Nanchang University, Jiangxi Province Key Laboratory of Oral Biomedicine, Jiangxi Province Clinical Research Center for Oral Disease, Nanchang, Jiangxi, China.

BACKGROUND This study included 32 patients with single missing teeth and alveolar bone defects and aimed to compare outcomes from guided bone regeneration with a gelatin/polylactic acid (GT/PLA) barrier membrane and a Guidor® bioresorbable matrix barrier dental membrane. MATERIAL AND METHODS A total of 32 participants were recruited in the clinical study, with single missing teeth and alveolar bone defects, requiring guided bone regeneration (32 missing teeth in total). They were randomly divided into the GT/PLA membrane group (experimental) and Guidor® membrane group (control) by the envelope method (n=16).

View Article and Find Full Text PDF

Aims: To compare the accuracy of marginal fit of CAD-CAM endocrown with two different preparation forms, i.e., endocrown with ferrule and endocrown without ferrule.

View Article and Find Full Text PDF

Aseptic loosening (AL) of artificial hip joints is the most common complication following hip replacement surgery. A total of eight patients diagnosed with AL following total hip arthroplasty (THA) undergoing total hip replacement and eight control patients diagnosed with avascular necrosis of femoral head (ANFH) or femoral neck fracture undergoing THA were enrolled. The samples of the AL group were from synovial tissue surrounding the lining/head/neck of the prosthesis, and the samples of the control group were from the synovium in the joint cavity.

View Article and Find Full Text PDF

Objective: By comparing the hip arthroplasty parameters planned with the AIHIP three-dimensional simulation surgery system, this study analyzes the accuracy of the new femoral-side "shoulder-to-shoulder" artificial anatomical marker positioning method in femoral-side prosthesis implantation and the prevention of leg length discrepancy in hip arthroplasty.

Methods: A retrospective collection of 47 patients who underwent initial total hip arthroplasty at our hospital from August 2020 to December 2022 and met the inclusion and exclusion criteria was used as the study subjects. The average age was 67.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!