A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Study of the Synergistic Influence of Plasma Electrolytic Oxidation and Wet Post-Treatment on the Surface of AA7075. | LitMetric

In this study, we enhanced the corrosion and microbial resistance of aluminum 7075 alloys by applying a thin layer of alumina through plasma electrolytic oxidation (PEO) in an alkali-silicate electrolyte. In addition, the influence of film sealing on coated aluminum alloy 7075 was studied in detail, specifically in oil and water at 100 °C after treatment. The surface and cross-sectional morphology, element composition, and phase composition of the PEO coatings were characterized by using scanning electron microscopy (SEM) assisted with energy-dispersive X-ray spectrometry (EDS) and X-ray diffraction (XRD), respectively. The corrosion resistance of the coating on AA7075 PEO was evaluated before and after post-treatment using hot water and hump oil at 100 °C. This assessment was conducted by using various electrochemical techniques, including open-circuit potential (OCP), linear polarization resistance (LPR), potentiodynamic polarization scan (PD), electrochemical impedance spectroscopy (EIS), and cyclic potentiodynamic scan (CPS). The results showed that the corrosion resistance of the AA7075 alloy was significantly improved after the PEO coating. The AA7075 + SF, among all of the examined alloys, exhibited superior corrosion properties, due to its fat sealing. This is probably due to the formation of a mixed fatty acid layer from oil on the surface of the AA7075 PEO, which synthesizes a hydrophobic layer. Interestingly, the samples treated with PEO showed a great resistance to microbial growth.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsabm.4c00528DOI Listing

Publication Analysis

Top Keywords

plasma electrolytic
8
electrolytic oxidation
8
surface aa7075
8
100 °c
8
corrosion resistance
8
coating aa7075
8
aa7075 peo
8
peo
6
aa7075
5
resistance
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!