A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Multi-Spark Electrohydraulic Shock Wave Generator with Adjustable Pressure Field Distribution and Beam Steering Capability. | LitMetric

A Multi-Spark Electrohydraulic Shock Wave Generator with Adjustable Pressure Field Distribution and Beam Steering Capability.

Front Urol

Thomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina 27708, USA.

Published: March 2023

Background And Objective: All clinical shock wave lithotripters produce an axisymmetric acoustic field without accounting for the anatomic features of the kidney or respiratory motion of the patient. This work presents a steerable and adjustable focusing electrohydraulic (SAFE) shock wave generator design with variable beam size and shape.

Materials And Methods: 90 electrohydraulic transducers are mounted concentrically on a spherical basin with adjustable connection to individual transducers. Each transducer consists of 45 3D-printed titanium microelectrodes embedded in epoxy with a tip diameter of 0.3 mm. All the transducers are arranged in 5 concentric rings and sub-divided into 6 sectors.

Results: By changing the connections of individual transducers, the focused pressure field produced by the transducer array can be either axisymmetric with a -6 dB focal width of 14.8 mm in diameter, or non-axisymmetric with a long axis of 22.7 mm and a short axis of 15.1 mm. The elongated beam produces a peak positive pressure of 33.7±4.1 MPa and comminution efficiency of 42.2±3.5%, compared to 36.2±0.7 MPa and 28.6±6.1% for axisymmetric beam after 150 pulses at 20 kV.

Conclusions: We have demonstrated that the SAFE shock wave generator can produce an elongated non-axisymmetric pressure field with higher stone comminution efficiency. The SAFE shock wave generator may provide a flexible and versatile design to achieve accurate, stable, and safe lithotripsy for kidney stone treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11349320PMC
http://dx.doi.org/10.3389/fruro.2023.1057723DOI Listing

Publication Analysis

Top Keywords

shock wave
20
wave generator
16
pressure field
12
safe shock
12
individual transducers
8
comminution efficiency
8
shock
5
wave
5
multi-spark electrohydraulic
4
electrohydraulic shock
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!