This study aims to establish joint fluid reference levels for Chromium (Cr) and Cobalt (Co) in a reference population of available fluid types. Method performance was evaluated on an existing urine matrix calibration method using inductively coupled plasma-mass spectrometry. Method performance characteristics, including intra- and inter-assay imprecision, accuracy, linearity, AMR (analytical measurement range), sensitivity, and carryover were determined in accordance with clinical laboratory standards. Additionally, analytical and clinical recoveries were assessed to investigate comparability between available joint fluid types and existing calibrators prepared in urine to demonstrate acceptability of a matrix-substitution design. 124 de-identified joint fluid samples submitted for unrelated testing were used to establish the reference levels. Reference levels were determined, by using the 97.5th percentile, to be <20.4 µg/L for Cr and <29.9 µg/L for Co. In addition, the presented method overcomes the lack of an ample volume of joint fluid to use for matrix matched calibrators by employing a urine-based calibration curve. The data demonstrate acceptable matrix comparability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11322749 | PMC |
http://dx.doi.org/10.1016/j.clinms.2017.11.003 | DOI Listing |
J Colloid Interface Sci
December 2024
Biological Physics Laboratory, Department of Physics and Astronomy, University of Manchester, Oxford Road, Schuster Building, Manchester M13 9PL, UK. Electronic address:
Hypothesis: Bioengineered monoclonal antibodies (mAbs) have gained significant recognition as medical therapies. However, during processing, storage and use, mAbs are susceptible to interfacial adsorption and desorption, leading to structural deformation and aggregation, and undermining their bioactivity. To suppress antibody surface adsorption, nonionic surfactants are commonly used in formulation.
View Article and Find Full Text PDFArthroplast Today
December 2024
Hospital Pavia Arecibo, Arecibo Orthopedic Institute, Arecibo, PR, USA.
Synovial fistula of the knee occurs when a defect in the joint capsule creates a connection between skin, bursa, and a near tissue, manifesting as an opening with continuous draining fluid or a cyst. This is a case of an 80-year-old male who developed a synovial fistula with cystic presentation 6 years after the primary total knee arthroplasty. Management included a total knee arthroplasty revision surgery with intraoperative identification of the fistula with methylene blue, and using a gelatin-thrombin matrix for closure.
View Article and Find Full Text PDFACS Appl Bio Mater
January 2025
Department of Materials Engineering, Indian Institute of Science Bangalore, Karnataka 560012, India.
The cartilage possesses limited regenerative capacity, necessitating advanced approaches for its repair. This study introduces a bioink designed for cartilage tissue engineering (TE) by incorporating ionically cross-linkable alginate into the photo-cross-linkable MuMA bioink, resulting in a double cross-linked interpenetrating network (IPN) hydrogel. Additionally, hyaluronic acid (HA), a natural component of cartilage and synovial fluid, was added to enhance the scaffold's properties.
View Article and Find Full Text PDFClin Radiol
December 2024
Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex HA7 4LP, UK.
Aims: To describe the imaging features of patients presenting with soft tissue masses and a provisional diagnosis of soft tissue tumours, for whom biopsy confirmed the presence of necrotising granulomata consistent with tuberculoma.
Material And Methods: A review of the histopathology database for patients who had a diagnosis of necrotising granulomata in nonspinal sites. Patients with bone and joint-based pathology were excluded.
J Clin Microbiol
January 2025
Department of Medical Microbiology, Infectious Diseases and Infection Prevention, Maastricht University Medical Centre, Maastricht, the Netherlands.
Unlabelled: Current laboratory protocols for periprosthetic joint infections (PJIs) involve a standard 10- to 14-day incubation period. However, recent evidence indicates considerable variability in the time to diagnosis (TTD) between acute and chronic PJIs. TTD is also influenced by the employed culture media and sample types.