Magnetic resonance (MR) images free of artefacts are of pivotal importance for MR-guided ion radiotherapy. This study investigates MR image quality for simultaneous irradiation in an experimental setup using phantom imaging as well asimaging. Observed artefacts are described within the study and their cause is investigated with the goal to find conclusions and solutions for potential future hybrid devices.An open MR scanner with a field strength of 0.25 T has been installed in front of an ion beamline. Simultaneous magnetic resonance imaging and irradiation using raster scanning were performed to analyze image quality in dedicated phantoms. Magnetic field measurements were performed to assist the explanation of observed artifacts. In addition,images were acquired by operating the magnets for beam scanning without transporting a beam.The additional frequency component within the isocenter caused by the fringe field of the horizontal beam scanning magnet correlates with the amplitude and frequency of the scanning magnet steering and can cause ghosting artifacts in the images. These are amplified with high currents and fast operating of the scanning magnet. Applying a real-time capable pulse sequencerevealed no ghosting artifacts despite a continuously changing current pattern and a clinical treatment plan activation scheme, suggesting that the use of fast imaging is beneficial for the aim of creating high quality in-beam MR images. This result suggests, that the influence of the scanning magnets on the MR acquisition might be of negligible importance and does not need further measures like extensive magnetic shielding of the scanning magnets.Our study delimited artefacts observed in MR images acquired during simultaneous raster scanning ion beam irradiation. The application of a fast pulse sequence showed no image artefacts and holds the potential that online MR imaging in future hybrid devices might be feasible.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/ad7453 | DOI Listing |
JAMA Netw Open
January 2025
Medical Oncology, The Ottawa Hospital Cancer Centre, University of Ottawa Faculty of Medicine, Ottawa, Ontario, Canada.
Importance: Evolving breast cancer treatments have led to improved outcomes but carry a substantial financial burden. The association of treatment costs with the cost-effectiveness of screening mammography is unknown.
Objective: To determine the cost-effectiveness of population-based breast cancer screening in the context of current treatment standards.
EJNMMI Phys
January 2025
Department of Nuclear Medicine, Lanzhou University Second Hospital, Lanzhou, 730030, China.
Purpose: The aim of the study was to investigate the value of SwiftScan Step-and-Shoot Continuous (SSC) scanning mode in enhancing image quality and to explore appropriate scanning parameters for reducing scan time.
Methods: This study was composed of a phantom study and two clinical tests. The differences in visual image quality scores, coefficient of variance (COV) of the background, image signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and recovery coefficient (RC) of the sphere were compared between SSC mode and traditional Step-and-Shoot (SS) mode in the phantom study.
Neurol Sci
January 2025
International Ph.D. Program in Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan.
Objectives: Fibromyalgia imposes a considerable burden of disability worldwide, and its therapies include rehabilitation interventions. However, the overall brain modulatory effects of rehabilitation interventions and their effects on clinical improvements in patients with fibromyalgia remain unclear. This systematic review of magnetic resonance imaging studies synthesised evidence for the brain modulatory effects of rehabilitation in patients with fibromyalgia.
View Article and Find Full Text PDFFollowing fracture fixation, fracture-related infection (FRI) is a common complication and requires systematic evaluation to allow for an optimal treatment strategy. A high index of suspicion is necessary for early and timely diagnosis, to diagnose occult infection, and to prevent untreated infections from worsening. Diagnosis of FRI includes evaluation based on history and clinical examination, surgical exploration, serum inflammatory markers, imaging modalities, microbiology, histopathology, and, when needed, molecular biology.
View Article and Find Full Text PDFJ Med Radiat Sci
January 2025
Discipline of Medical Imaging Sciences, Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia.
Introduction: Quality assurance (QA) in medical imaging ensures consistently high-quality images at acceptable radiation doses. However, the applicability of the chest X-ray (CXR) QA tool in images with pathology, particularly infectious diseases like COVID-19, has not been explored. This study examines the utility of the European Guidelines for image quality in QA of CXRs with varying severity and types of infectious disease.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!