A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliable Contactless Monitoring of Heart Rate, Breathing Rate, and Breathing Disturbance During Sleep in Aging: Digital Health Technology Evaluation Study. | LitMetric

Background: Longitudinal monitoring of vital signs provides a method for identifying changes to general health in an individual, particularly in older adults. The nocturnal sleep period provides a convenient opportunity to assess vital signs. Contactless technologies that can be embedded into the bedroom environment are unintrusive and burdenless and have the potential to enable seamless monitoring of vital signs. To realize this potential, these technologies need to be evaluated against gold standard measures and in relevant populations.

Objective: We aimed to evaluate the accuracy of heart rate and breathing rate measurements of 3 contactless technologies (2 undermattress trackers, Withings Sleep Analyzer [WSA] and Emfit QS [Emfit]; and a bedside radar, Somnofy) in a sleep laboratory environment and assess their potential to capture vital signs in a real-world setting.

Methods: Data were collected from 35 community-dwelling older adults aged between 65 and 83 (mean 70.8, SD 4.9) years (men: n=21, 60%) during a 1-night clinical polysomnography (PSG) test in a sleep laboratory, preceded by 7 to 14 days of data collection at home. Several of the participants (20/35, 57%) had health conditions, including type 2 diabetes, hypertension, obesity, and arthritis, and 49% (17) had moderate to severe sleep apnea, while 29% (n=10) had periodic leg movement disorder. The undermattress trackers provided estimates of both heart rate and breathing rate, while the bedside radar provided only the breathing rate. The accuracy of the heart rate and breathing rate estimated by the devices was compared with PSG electrocardiogram-derived heart rate (beats per minute) and respiratory inductance plethysmography thorax-derived breathing rate (cycles per minute), respectively. We also evaluated breathing disturbance indexes of snoring and the apnea-hypopnea index, available from the WSA.

Results: All 3 contactless technologies provided acceptable accuracy in estimating heart rate (mean absolute error <2.12 beats per minute and mean absolute percentage error <5%) and breathing rate (mean absolute error ≤1.6 cycles per minute and mean absolute percentage error <12%) at 1-minute resolution. All 3 contactless technologies were able to capture changes in heart rate and breathing rate across the sleep period. The WSA snoring and breathing disturbance estimates were also accurate compared with PSG estimates (WSA snore: r=0.76; P<.001; WSA apnea-hypopnea index: r=0.59; P<.001).

Conclusions: Contactless technologies offer an unintrusive alternative to conventional wearable technologies for reliable monitoring of heart rate, breathing rate, and sleep apnea in community-dwelling older adults at scale. They enable the assessment of night-to-night variation in these vital signs, which may allow the identification of acute changes in health, and longitudinal monitoring, which may provide insight into health trajectories.

International Registered Report Identifier (irrid): RR2-10.3390/clockssleep6010010.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11387924PMC
http://dx.doi.org/10.2196/53643DOI Listing

Publication Analysis

Top Keywords

heart rate
24
breathing rate
24
rate breathing
20
vital signs
16
rate
12
contactless technologies
12
breathing
8
breathing disturbance
8
monitoring vital
8
older adults
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!