Does extreme weight loss after bariatric surgery alter spinopelvic parameters and ameliorate back pain? A retrospective case study.

Jt Dis Relat Surg

SBÜ, Atatürk Sanatoryum Eğitim ve Araştırma Hastanesi, Ortopedi ve Travmatoloji Kliniği, 06000 Keçiören, Ankara, Türkiye.

Published: July 2024

Objectives: The aim of this study was to evaluate the effect of extreme weight loss on low back pain and spinopelvic parameters.

Patients And Methods: A total of 45 patients (11 males, 34 females; mean age: 40.2±9.4 years; range, 18 to 57 years) who had bariatric surgery between January 2018 and December 2021 were retrospectively analyzed. Radiological spinopelvic parameters including lumbar lordosis (LL), pelvic incidence (PI), spinopelvic harmony (when PI is within LL±10°), pelvic tilt (PT) and sacral slope (SS) were evaluated pre- and postoperatively. Clinical outcomes were assessed using the Visual Analog Scale-Back Pain (VAS-BP) and Oswestry Disability Index (ODI).

Results: The mean BMI loss at the end of the first year after surgery was 28.1±6.7% (range, 21 to 36%). The mean PI was 55.75°±12.47° preoperatively and 53.64°±11.86° at one year and the difference was -3.10°±5.25 (p=0.02), 1.10°±4.95° for PT (p=0.46), -2,70°±3.50° for SS (p<0.001), and 3.1±6.55 for LL (p<0.001). At one year, spinopelvic harmony remained unchanged in 31 patients, nine patients regained harmony, and was lost in five patients who had previously. No significant correlation between alterations in spinopelvic alignment and ODI scores was shown (p<0.05). The mean VAS-BP score was 40±30 mm preoperatively, and 20±3.5 mm postoperatively, indicating a difference of -39±29.5 (p<0.001). The mean ODI was 34.71±20.87 preoperatively, and 16±24 postoperatively, indicating a difference of -15±13 (p<0.001). Subgroup analyses showed that the change in SS was more pronounced with regard to PT change, particularly in young and female patients with >10 kg/m reduction in BMI (p<0.001).

Conclusion: Weight loss after bariatric surgery improves lower back pain leading to changes in PT without affecting SS and altering PI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11411890PMC
http://dx.doi.org/10.52312/jdrs.2024.1683DOI Listing

Publication Analysis

Top Keywords

extreme weight
8
weight loss
8
bariatric surgery
8
spinopelvic parameters
8
loss bariatric
4
surgery alter
4
spinopelvic
4
alter spinopelvic
4
parameters ameliorate
4
ameliorate pain?
4

Similar Publications

Introduction: In all sectors of the economy, including livestock production, there is an increasing focus on sustainability criteria. The carbon footprint is therefore an important target value in pig production. The aim is to minimize this value.

View Article and Find Full Text PDF

Field pennycress () is a new biofuel winter annual crop with extreme cold hardiness and a short life cycle, enabling off-season integration into corn and soybean rotations across the U.S. Midwest.

View Article and Find Full Text PDF

Primary uterine non-Hodgkin lymphoma (NHL) is rarely reported, as its incidence is extremely low. We describe a 72 year old patient with primary uterine non-Hodgkin's lymphoma stage IV, diffuse B-cell large cells, who responded well to cytotoxic chemotherapy (R-CHOP). Radiological investigations exhibited certain characteristics, including magnetic resonance T2 weighted imaging, enhanced scanning, diffusion weighted imaging and apparent diffusion coefficient values.

View Article and Find Full Text PDF

Soft, Modular Power for Composing Robots with Embodied Energy.

Adv Mater

January 2025

Department of Mechanical and Aerospace Engineering, Cornell University, 124 Hoy Road, Ithaca, NY, 14850, USA.

The adaptable, modular structure of muscles, combined with their confluent energy storage allows for numerous architectures found in nature: trunks, tongues, and tentacles to name some more complex ones. To provide an artificial analog to this biological soft muscle, a self-powered, soft hydrostat actuator is presented. As an example of how to use these modules, a worm robot is assembled where the near totality of the body stores electrochemical potential.

View Article and Find Full Text PDF

In this study, the degradation behavior of poly(lactic acid) nanocomposite films (PLA/Hec-g@PS) under extreme natural environments was investigated, and the degraded PLA based films were applied to adsorb Cu(II). During the early and midstages of degradation, the surface roughness and crack propagation rate of PLA/Hec-g@PS films were significantly lower than those of PLA films. This could be due to the fact that Hec-g@PS enhanced the interaction forces between C-O-C + CH and C═O in the PLA chains, thereby mitigating the degradation of PLA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!