Vibrational spectroscopy combined with machine learning has a great potential for forensic research. Portable Raman spectrometers are already being used by law-enforcement agencies to identify drugs. Several new technologies based on vibrational spectroscopy, that can be used in forensic science to analyze documents, gunshot traces, cloths, soil, hair, nails and lacquer, are being developed nowadays. The article considers the use of vibrational spectroscopy in forensic practice for conducting serological studies with an emphasis on the development of a universal method of identifying the main secretions of the body. The method allows to determine the time elapsed since the trace was made, as well as the phenotypic profile of host, including sex, race and age.

Download full-text PDF

Source
http://dx.doi.org/10.17116/sudmed20246704169DOI Listing

Publication Analysis

Top Keywords

spectroscopy forensic
12
vibrational spectroscopy
12
combined machine
8
[vibrational spectroscopy
4
forensic
4
forensic purposes
4
purposes combined
4
machine learning]
4
learning] vibrational
4
spectroscopy combined
4

Similar Publications

Evaluation of Subetadex-α-methyl, a Polyanionic Cyclodextrin Scaffold, as a Medical Countermeasure against Fentanyl and Related Opioids.

ACS Cent Sci

December 2024

Physical and Life Sciences Directorate, Biosciences and Biotechnology Division, Global Security Directorate, Forensic Science Center, and Materials Science Division, Lawrence Livermore National Laboratory, Livermore, California 94550, United States.

Subetadex-α-methyl (SBX-Me), a modified, polyanionic cyclodextrin scaffold, has been evaluated for its utilization as a medical countermeasure (MCM) to neutralize the effects of fentanyl and related opioids. Initial toxicity assays demonstrate that SBX-Me has a nontoxic profile, comparable to the FDA-approved cyclodextrin-based drug Sugammadex. Pharmacokinetic analysis showed rapid clearance of SBX-Me with an elimination half-life of ∼7.

View Article and Find Full Text PDF

Photonic platform coupled with machine learning algorithms to detect pyrolysis products of crack cocaine in saliva: A proof-of-concept animal study.

Spectrochim Acta A Mol Biomol Spectrosc

December 2024

Innovation Center in Salivary Diagnostics and Nanobiotechnology, Department of Physiology, Institute of Biomedical Sciences, Federal University of Uberlandia (UFU), Uberlandia, MG, Brazil. Electronic address:

The non-invasive detection of crack/cocaine and other bioactive compounds from its pyrolysis in saliva can provide an alternative for drug analysis in forensic toxicology. Therefore, a highly sensitive, fast, reagent-free, and sustainable approach with a non-invasive specimen is relevant in public health. In this animal model study, we evaluated the effects of exposure to smoke crack cocaine on salivary flow, salivary gland weight, and salivary composition using Attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy.

View Article and Find Full Text PDF

Tramadol as a fentanyl adulterant: Prevalence and management in a ToxIC Fentalog study prospective cohort.

Am J Emerg Med

December 2024

Icahn School of Medicine at Mount Sinai, Center for Research on Emerging Substances, Poisoning, Overdose, and New Discoveries (RESPOND), NYC Health + Hospitals/Elmhurst, New York, NY, USA.

Background: Tramadol is an adulterant of illicit opioids. As it is a serotonin-norepinephrine reuptake inhibitor as well as a μ-opioid agonist, tramadol adulteration may worsen overdose signs and symptoms or affect the amount of naloxone patients receive.

Methods: This is a multicenter, prospective cohort of adult patients with suspected opioid overdoses who presented to one of eight United States emergency departments and were included in the Toxicology Investigators Consortium's Fentalog Study.

View Article and Find Full Text PDF

This work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity.

View Article and Find Full Text PDF

Drug checking services (DCS) are entities that allow recreational drug users to have street drug samples analyzed. Diverse analytical methods are applied for DCS, ranging from test strips to mass spectrometry (MS). This work evaluates the performance and utility of common methodologies used for DCS operating with off-site drug testing, while additionally assessing the potential of gas chromatography coupled to vapor phase infrared spectroscopy (GC-IR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!