A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic accuracy of an exhaled breath test for TB in hospitalized patients with cough or risk. | LitMetric

Diagnostic accuracy of an exhaled breath test for TB in hospitalized patients with cough or risk.

Int J Tuberc Lung Dis

Beth Israel Deaconess Medical Center, Boston, MA, USA;, Harvard Medical School, Boston, MA, USA.

Published: September 2024

INTRODUCTIONClosing the TB diagnostic gap is an urgent priority, for which non-sputum-based tests are needed. We evaluated the diagnostic accuracy of Aeonose, an exhaled breath test (EBT), as a TB triage test.METHODSPatients with cough or TB risk factors admitted to a tertiary hospital in Lima, Peru, were prospectively enrolled and underwent EBT. We evaluated EBT sensitivity and specificity for diagnosing pulmonary TB using culture and Xpert as primary and secondary reference standards and conducted stratified analyses based on risk factors.RESULTSEBT sensitivity was 85% (95% CI 72.9-93.4), and specificity was 51% (95% CI 46.0-56.6) in the training cohort ( = 417). EBT sensitivity was 70% (95% CI 47.1-86.8), and specificity was 54% (95% CI 44.8-63.6) in the validation cohort (n = 139) using the culture reference standard, with higher sensitivity (78%) when using the Xpert reference standard ( = 156). Sensitivity (60%) and specificity (48%) were lower when patients with prior TB were included. In a subset of participants randomly selected for interviews, 94% (15/16) preferred EBT to sputum-based testing.CONCLUSIONSEBT had moderate sensitivity and low specificity as a TB triage test in this hospitalised cohort with cough or risk factors. Diagnostic accuracy was lower in people with prior TB..

Download full-text PDF

Source
http://dx.doi.org/10.5588/ijtld.24.0148DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
12
cough risk
12
exhaled breath
8
breath test
8
risk factors
8
ebt sensitivity
8
reference standard
8
sensitivity
6
ebt
5
specificity
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!