Background And Purpose: The purpose of this study was to assess the dosimetric improvements achieved in prostate stereotactic body radiotherapy (SBRT) treatment within the PROMETHEUS and NINJA trials using an in-house real-time position monitoring system, SeedTracker.
Methods And Materials: This study considered a total of 127 prostate SBRT patients treated in the PROMETHEUS (ACTRN12615000223538) and NINJA (ACTRN12618001806257) clinical trials. The SeedTracker position monitoring system was utilized for real-time position monitoring with a 3-mm position tolerance. The doses delivered to the clinical target volume (CTV), rectum, and bladder were assessed by incorporating the actual target position during treatment. The dose that would have been delivered without monitoring was also assessed by incorporating the observed position deviations.
Results: Treatment with position corrections resulted in a mean (range) CTV D99 difference of -0.3 (-1.0 to 0.0) Gy between the planned and delivered dose. Without corrections, this difference would have been -0.6 (-3.7 to 0.0) Gy. Not correcting for position deviations resulted in a statistically significant difference between the planned and delivered CTV D99 ( < 0.05). The mean (range) dose difference between the planned and delivered D2cc of the rectum and bladder for treatment with position corrections was -0.1 (-3.7 to 4.7) Gy and -0.1 (-1.7 to 0.5) Gy, respectively. Without corrections, these differences would have been -0.6 (-6.1 to 4.7) Gy and -0.2 (-2.5 to 0.9) Gy.
Conclusions: SeedTracker improved clinical dose volume compliance in prostate SBRT. Without monitoring and corrections, delivered dose would significantly differ from the planned dose.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11341385 | PMC |
http://dx.doi.org/10.3389/fonc.2024.1372968 | DOI Listing |
Front Sports Act Living
January 2025
Graduate School of Health and Sports Science, Juntendo University, Inzai, Japan.
Introduction: Marathon running has become increasingly popular among amateur athletes, many of whom maintain speeds of 8-9 km/h. However, existing methods for estimating oxygen consumption (VO) during running and walking-such as the American College of Sports Medicine (ACSM) equations and commercial activity monitors-often lack accuracy and transparency. This study introduces the Hata-Yanagiya Physical Activity Calculation (HYPAC) system, a novel approach for estimating VO using Global Positioning System (GPS) and map data.
View Article and Find Full Text PDFIntensive Crit Care Nurs
January 2025
Department of Intensive Care Medicine, Hospital Universitario de La Princesa, Madrid, Spain; Centro de investigación en red CIBERES de enfermedades respiratorias, Instituto de Salud, Carlos III, Madrid, Spain. Electronic address:
Objectives: To analyse the effects on respiratory function, lung volume and the regional distribution of ventilation and perfusion of routine postural repositioning in mechanically ventilated critically ill patients.
Methods: Prospective descriptive physiological study. We evaluated gas-exchange, lung mechanics, and Electrical Impedance Tomography (EIT) determined end-expiratory lung impedance and regional ventilation and perfusion distribution in five body positions: supine-baseline (S1); first lateralisation at 30° (L1); second supine position (S2), second contralateral lateralisation (L2) and third final supine position (S3).
Sci Rep
January 2025
China Academy of Railway Sciences Co. Ltd, Beijing, 100081, China.
The construction of tunnels can easily trigger the reactivation of old landslide bodies, posing a threat to the transportation safety. In this study, using methods such as engineering geological investigation, slope deformation monitoring, deep displacement monitoring, and numerical simulation, the interaction between landslides and tunnels was investigated from the perspective of landslide deformation and failure characteristics. The Walibie Tunnel (WLBT) of Shangri-La to Lijiang (XL) expressway was taken as an example.
View Article and Find Full Text PDFRev Clin Esp (Barc)
January 2025
Servicio de Medicina Interna, Hospital Universitario General de Valencia; Grupo de trabajo de Insuficiencia Cardíaca yFibrilación Auricular de la SEMI (ICYFA), Spain. Electronic address:
This document provides a comprehensive analysis of the use of point-of-care ultrasound in heart failure (HF), offering detailed recommendations on echocardiography, lung ultrasound, and venous ultrasound. These advanced imaging techniques allow for an accurate, detailed, and non-invasive evaluation of heart failure, facilitating rapid and effective clinical decision-making. Echocardiography enables a rapid assessment of cardiac function at the point of care, enhancing traditional physical examination and being essential for the management of heart failure (HF).
View Article and Find Full Text PDFLancet Neurol
February 2025
Department of Clinical Neurological Sciences, University of Western Ontario, London, ON, Canada; Department of Cognitive Neurology, St Joseph's Health Care London, London, ON, Canada. Electronic address:
Background: No treatments exist for apathy in people with frontotemporal dementia. Previously, in a randomised double-blind, placebo-controlled, dose-finding study, intranasal oxytocin administration in people with frontotemporal dementia improved apathy ratings on the Neuropsychiatric Inventory over 1 week and, in a randomised, double-blind, placebo-controlled, crossover study, a single dose of 72 IU oxytocin increased blood-oxygen-level-dependent signal in limbic brain regions. We aimed to determine whether longer treatment with oxytocin improves apathy in people with frontotemporal dementia.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!