A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Molecular dynamics and experimental analysis of energy behavior during stress relaxation in magnetorheological elastomers. | LitMetric

AI Article Synopsis

  • The study investigates the performance and failure resistance of magnetorheological elastomers (MRE), focusing on how stress relaxation affects their molecular and mechanical properties.
  • The research utilizes molecular dynamics simulations to better understand the stress relaxation process in MREs made with varying amounts of magnetic iron, finding a significant decrease in stored energy across all models.
  • Results indicate that the MRE with 80 wt% magnetic iron exhibits the highest final stored energy due to stronger molecular interactions, highlighting the potential for MD simulations as a valuable tool in MRE material design and failure prevention.

Article Abstract

The diverse applications of magnetorheological elastomer (MRE) drive efforts to understand consistent performance and resistance to failure. Stress relaxation can lead to molecular chain deterioration, degradation in stiffness and rheological properties, and ultimately affect the life cycle of MRE. However, quantifying the energy and molecular dynamics during stress relaxation is challenging due to the difficulty of obtaining atomic-level insights experimentally. This study employs molecular dynamics (MD) simulation to elucidate the stress relaxation in MRE during constant strain. Magnetorheological elastomer models incorporating silicone rubber filled with varying magnetic iron particles (50-80 wt%) were constructed. Experimental results from an oscillatory shear rheometer showed the linear viscoelastic region of MRE to be within 0.001-0.01% strain. The simulation results indicated that stress relaxation has occurred, with stored energies decreased by 8.63-52.7% in all MRE models. Monitoring changes in energy components, the highest final stored energy (12,045 kJ) of the MRE model with 80 wt% Fe particles was primarily attributed to stronger intramolecular and intermolecular interactions, revealed by higher potential energy (3262 kJ) and van der Waals energy (- 2717.29 kJ). Stress relaxation also altered the molecular dynamics of this MRE model as evidenced by a decrease in kinetic energy (9362 kJ) and mean square displacement value (20,318 Å). The MD simulation provides a promising quantitative tool for elucidating stress relaxation, preventing material failure and offering insights for the design of MRE in the nanotechnology industry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11345436PMC
http://dx.doi.org/10.1038/s41598-024-70459-7DOI Listing

Publication Analysis

Top Keywords

stress relaxation
28
molecular dynamics
16
magnetorheological elastomer
8
mre
8
mre model
8
energy
7
stress
7
relaxation
7
molecular
5
dynamics experimental
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!