Comparison of nociceptor properties using electrophysiology in preclinical models of osteoarthritis.

Neurosci Lett

Departments of Pharmacology and Anaesthesia, Pain Management & Perioperative Medicine, Dalhousie University, 5850 College Street, Halifax, Nova Scotia, B3H 4R2, Canada. Electronic address:

Published: September 2024

Osteoarthritis (OA) pain originates in the joint by sensitization of articular nociceptors. While behavioural assessments provide valuable information regarding pain symptoms, the techniques are subjective and open to interpretation by the experimenter. This study used in vivo electrophysiological approaches to measure objectively joint nociceptor properties in three rodent models of OA. Single unit extracellular recordings of joint mechanosensitive afferents were carried out in male and female rats following either (1) transection of the medial meniscus (MMT: post-traumatic OA), (2) intra-articular injection of sodium monoiodoacetate (MIA: chemically-induced OA), or (3) intra-articular injection of lysophosphatidic acid (LPA: neuropathic OA). In naïve male control rats, the mechanical threshold of joint mechanonociceptors (23.5 ± 1.8 mNm) was significantly reduced with MMT (9.4 ± 1.1 mNm) and MIA (15.1 ± 1.6 mNm). In females, the mechanical threshold of naïve rats (23.2 ± 3.1 mNm) was reduced following induction of MMT (8.3 ± 1.0 mNm) and LPA (10.6 ± 2.2 mNm). Afferent firing frequency increased in male MMT (∼275 %), LPA (∼175 %), MIA (225 %), and female MMT (∼146 %), LPA (∼200 %), and MIA (∼192 %). Mechanical threshold and evoked firing were negatively correlated in all models for both sexes except LPA rats (male + female) and female MMT. These data indicate that MMT, MIA, and LPA induce peripheral sensitization of joint afferents thereby validating their use in OA pain studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neulet.2024.137950DOI Listing

Publication Analysis

Top Keywords

mechanical threshold
12
nociceptor properties
8
intra-articular injection
8
mnm reduced
8
female mmt
8
mmt
7
lpa
6
mnm
6
joint
5
mia
5

Similar Publications

Background: Extracorporeal membrane oxygenation (ECMO) is increasingly used as a bridge to lung transplantation. Although other mechanical circulatory support devices have been associated with anti-human leukocyte antigen antibody formation, including de novo donor-specific antibodies (dnDSA), it is unknown whether ECMO is a sensitizing exposure.

Methods: This was a single-center retrospective cohort study of lung transplant recipients.

View Article and Find Full Text PDF

Cancer pain is one of the most common symptoms in patients with advanced cancer. In this study, we aimed to investigate the effects of the -related gene C (MrgC) receptors on bone cancer pain. Mechanical withdrawal threshold (MWT) and thermal withdrawal latency (TWL) were measured after the inoculation of Walker 256 mammary gland carcinoma cells into the tibia of adult Sprague-Dawley rats.

View Article and Find Full Text PDF

Frictional motion is mediated by rapidly propagating ruptures that detach the ensemble of contacts forming the frictional interface between contacting bodies. These ruptures are similar to shear cracks. When this process takes place in natural faults, these rapid ruptures are essentially earthquakes.

View Article and Find Full Text PDF

Background And Purpose:  This study updates 2 parallel systematic reviews and meta-analyses from 2012, which established the 1-year radiostereometric (RSA) migration thresholds for tibial components of total knee replacements (TKR) based on the risk of late revision for aseptic loosening from survival studies. The primary aim of this study was to determine the (mis)categorization rate of the 2012 thresholds using the updated review as a validation dataset. Secondary aims were evaluation of 6-month migration, mean continuous (1- to 2-year) migration, and fixation-specific thresholds for tibial component migration.

View Article and Find Full Text PDF

Instabilities in the form of periodic or irregular waves at the fluid interface have been demonstrated in microchannel electrokinetic flows with conductivity gradients when the applied electric field is above a threshold value. Most prior studies on electrokinetic instabilities (EKI) are restricted to Newtonian fluids though many of the chemical and biological samples in microfluidic applications exhibit non-Newtonian characteristics. We present in this work an experimental study of the effects of fluid shear thinning on the development of EKI waves through the addition of a small amount of xanthan gum (XG) polymer to both the high- and low-concentration Newtonian buffer solutions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!