Optimal environmental sampling conditions for electrostatic aerosol-to-hydrosol collection of airborne viruses.

J Hazard Mater

Department of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea. Electronic address:

Published: October 2024

Due to adverse effects of viral outbreaks on human health, accurate detection of airborne pathogens is essential. Among many methods available for bioaerosol sampling, electrostatic precipitation (ESP) has been used to directly collect bioaerosols as hydrosols. The performance of an ESP sampler depends on its design, operational and environmental parameters such as air relative humidity (RH), air temperature, sampling liquid type and liquid temperature. Thus, it is essential to identify and maintain optimal conditions throughout sampling process to operate the sampler at its highest capacity. This study provides crucial insights into parameters that affect the collection efficiency of the aerosol-to-hydrosol ESP sampler and its virus recovery. The results indicate that air temperature does not affect collection efficiency, meanwhile, air RH, sampling liquid temperature, and salt concentration are the main parameters that significantly affect collection efficiency. Likewise, when deionized water is used as sampling liquid, hydrogen peroxide concentration increases proportionally with increasing air RH, resulting in significant decrease of virus viability. Consequently, for ESP samplers similar to our study, the following conditions are recommended: air RH of 55-65%, air and sampling liquid temperature of 37 °C, and a mixture of 10-20 mM ascorbic acid in PBS as sampling liquid.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2024.135491DOI Listing

Publication Analysis

Top Keywords

sampling liquid
20
liquid temperature
12
affect collection
12
collection efficiency
12
sampling
8
esp sampler
8
air temperature
8
parameters affect
8
air sampling
8
air
7

Similar Publications

Automated High-Throughput Affinity Capture-Mass Spectrometry Platform with Data-Independent Acquisition.

J Proteome Res

January 2025

Discovery Research, AbbVie, Inc., 1 North Waukegan Rd., North Chicago, Illinois 60064, United States.

Affinity capture (AC) combined with mass spectrometry (MS)-based proteomics is highly utilized throughout the drug discovery pipeline to determine small-molecule target selectivity and engagement. However, the tedious sample preparation steps and time-consuming MS acquisition process have limited its use in a high-throughput format. Here, we report an automated workflow employing biotinylated probes and streptavidin magnetic beads for small-molecule target enrichment in the 96-well plate format, ending with direct sampling from EvoSep Solid Phase Extraction tips for liquid chromatography (LC)-tandem mass spectrometry (MS/MS) analysis.

View Article and Find Full Text PDF

Compound-specific stable isotope analysis (CSIA) using liquid chromatography-isotope ratio mass spectrometry (LC-IRMS) is a powerful tool for determining the isotopic composition of carbon in analytes from complex mixtures. However, LC-IRMS methods are constrained to fully aqueous eluents. Previous efforts to overcome this limitation were unsuccessful, as the use of organic eluents in LC-IRMS was deemed impossible.

View Article and Find Full Text PDF

Metabolic dysfunction-associated steatotic liver disease (MASLD) describes liver diseases caused by the accumulation of triglycerides in hepatocytes (steatosis) as well as the resulting inflammation and fibrosis. Previous studies have demonstrated that accumulation of fat in visceral adipose tissue compartments and the liver is associated with alterations in the circulating levels of some amino acids, notably glutamate. This study aimed to investigate the associations between circulating amino acids, particularly glutamate, and MASLD.

View Article and Find Full Text PDF

Background: In a previous study, we found that Atractylodes macrocephala and Paeoniae radix (AM-PR) was useful for the alleviation of functional constipation (FC). However, the precise mechanism underlying the compatibility between AM and PR in the treatment of FC remains uncertain. This study aims to analyze the pharmacokinetic differences in the active ingredients in the blood of rat models with FC when applied individually and in combination with AM-PR.

View Article and Find Full Text PDF

Introduction: The use of weight loss supplements is increasing, often driven by online marketing. However, many of these supplements are adulterated with undeclared pharmaceutical substances, potentially posing significant health risks. We investigated the presence of sibutramine and sildenafil in weight loss supplements and assessed the associated clinical outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!