A machine learning system for artificial ligaments with desired mechanical properties in ACL reconstruction applications.

J Mech Behav Biomed Mater

School of Biomedical Engineering, Sun Yat-sen University, Shenzhen 518107, China. Electronic address:

Published: November 2024

The anterior cruciate ligament is one of the important tissues to maintain the stability of the human knee joint, but it is difficult for this ligament to self-heal after injury. Consequently, transplantation of artificial ligaments (ALs) has gained widespread attention as an important alternative treatment method in recent years. However, accurately predicting the intricate mechanical properties of ALs remains a formidable challenge, particularly when employing theoretical frameworks such as braiding theory. This obstacle presents a significant impediment to achieving optimal AL design. Therefore, in this study, a high-precision machine learning model based on an artificial neural network was developed to rapidly and accurately predict the mechanical properties of ALs. The results showed that the proposed model achieved a reduction of 45.22% and 50.17% in the normalized root mean square error on the testing set when compared to traditional machine learning models (Random Forest and Support Vector Machine), demonstrating its higher accuracy. In addition, the design of ALs with desired mechanical properties was achieved by optimizing the braiding parameters, and its effectiveness was verified through experiments. The mechanical properties of the prepared ALs were able to fully meet the desired targets and were at least 2% higher. Finally, the influence weights of different braiding parameters on the mechanical properties of ALs were analyzed by feature importance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2024.106691DOI Listing

Publication Analysis

Top Keywords

mechanical properties
24
machine learning
12
properties als
12
artificial ligaments
8
desired mechanical
8
braiding parameters
8
mechanical
6
properties
6
als
6
machine
4

Similar Publications

Age is associated with increased tissue stiffness and a higher risk of low back pain, particularly in older, sedentary workers who spend long periods sitting. This study explored how trunk stiffness changes with age and its relationship with posture during prolonged sitting in a sample of 37 women aged 20-65 years. Age was assessed as both Chronological Age and Fitness Age, with trunk stiffness measured using a passive trunk flexion apparatus.

View Article and Find Full Text PDF

Anti-inflammatory coupled anti-angiogenic airway stent effectively suppresses tracheal in-stents restenosis.

J Nanobiotechnology

January 2025

Department of Interventional Radiology, Key Laboratory of Interventional Radiology of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450001, China.

Excessive vascularization during tracheal in-stent restenosis (TISR) is a significant but frequently overlooked issue. We developed an anti-inflammatory coupled anti-angiogenic airway stent (PAGL) incorporating anlotinib hydrochloride and silver nanoparticles using advanced electrospinning technology. PAGL exhibited hydrophobic surface properties, exceptional mechanical strength, and appropriate drug-release kinetics.

View Article and Find Full Text PDF

Background: The excessive use of antibiotics is a major contributor to the global issue of antimicrobial resistance (AMR), a significant threat to human and animal health. Hence, assessing new strategies for managing Multi-Drug Resistant (MDR) microorganisms is vital. In this study, the use of mechanically isolated mature adipose cells (MIMACs) and their lysate (Adipolysate) as a new sustainable antimicrobial agent was assessed against Methicillin-resistant Staphylococcus aureus (MRSA).

View Article and Find Full Text PDF

In the current investigation, the efficiency inhibition of two newly synthesized bi-pyrazole derivatives, namely 2,3-bis[(bis((1 H-pyrazol-1-yl) methyl) amino)] pyridine (Tetra-Pz-Ortho) and 1,4-bis[(bis((1 H-pyrazol-1-yl) methyl) amino)] benzene (Tetra-Pz-Para) for corrosion of carbon steel (C&S) in 1 M HCl medium was evaluated. A Comparative study of inhibitor effect of Tetra-Pz-Ortho and Tetra-Pz-Para was conducted first using weight loss method and EIS (Electrochemical Impedance Spectroscopy) and PDP (Potentiodynamic Polarisation) techniques. Tetra-Pz-Ortho and Tetra-Pz-Para had a maximum inhibition efficacy of 97.

View Article and Find Full Text PDF

Ion beam induced secondary electron tomography of acrylonitrile-styrene-acrylate/polycarbonate polymer blends for fused filament fabrication and injection moulding.

Sci Rep

January 2025

Departamento de Ciencia de los Materiales e Ingeniería Metalúrgica y Química Orgánica, IMEYMAT, Universidad de Cádiz, Campus Río San Pedro, 11510, Puerto Real, Cádiz, Spain.

Polymer blending is an interesting strategy to broaden the combination of properties available for a variety of applications. To understand the behaviour of the new materials obtained as well as the influence of the fabrication parameters used, methods to analyse the distribution of polymers in the blend with resolution below the micrometer are required. In this work, we demonstrate the capability of focused ion beam (FIB) tomography to provide 3D information of the polymer distribution in objects obtained by blending acrylonitrile-styrene-acrylate (ASA) with polycarbonate (PC) (50 wt%), fabricated by Fused Filament Fabrication (FFF) and by Injection Moulding (IM).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!