A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The morphology of internal elastic lamina corrugations in arteries under physiological conditions. | LitMetric

The morphology of internal elastic lamina corrugations in arteries under physiological conditions.

Morphologie

Department of Chemical Engineering, University of Pittsburgh, 15261 Pittsburgh, PA, USA; Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 15261 Pittsburgh, PA, USA; McGowan Institute of Regenerative Medicine, University of Pittsburgh, 15261 Pittsburgh, PA, USA. Electronic address:

Published: December 2024

Background: In elastic and resistance arteries, an elastin-rich membrane, the Internal Elastic Lamina (IEL), separates the tunica intima from the underlying tunica media. The IEL often appears wrinkled or corrugated in histological images. These corrugations are sometimes ascribed to vessel contraction ex vivo, and to fixation artifacts, and therefore regarded as not physiologically relevant. We examine whether the IEL remains corrugated even under physiological conditions.

Methods: The diameters of carotid arteries of anesthetized pigs were measured by ultrasound. The arteries were then excised, inflated within a conical sleeve, fixed, and imaged by confocal microscopy. The conical sleeve allows fixing each artery across a wide range of diameters, which bracket its ultrasound diameter. Thus the study was designed to quantify how corrugations change with diameter for a single artery, and test whether corrugations exist when the fixed artery matches the ultrasound diameter.

Results: At diameters below the ultrasound diameter (i.e. when the artery was constricted as compared to ultrasound conditions), the IEL corrugations were found to decrease significantly with increasing diameter, but not fully flatten at the ultrasound diameter. The contour length of the IEL was found to be roughly 10% larger than the circumference of the artery measured by ultrasound. Since ultrasound was conducted with the animal under general anesthesia which induces vasodilation, the physiological diameter is likely to be smaller than the ultrasound diameter, and hence the arteries are likely to have a higher level of corrugation under physiological conditions. For arterial cross sections constricted below the ultrasound diameter, the IEL contour length decreased roughly with the square root of the diameter.

Conclusion: The primary conclusions of this study are: a) the IEL is corrugated when the artery is constricted and flattens as the artery diameter increases; b) the IEL is corrugated under physiological conditions and has a contour length at least 10% more than the physiological arterial diameter; and c) the IEL despite being relatively stiffer than the surrounding arterial layers, does not behave like an inextensible membrane.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.morpho.2024.100902DOI Listing

Publication Analysis

Top Keywords

ultrasound diameter
20
physiological conditions
12
contour length
12
ultrasound
10
diameter
10
iel
9
internal elastic
8
elastic lamina
8
corrugated physiological
8
measured ultrasound
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!