A Novel Method and Python Library for ECG Signal Quality Assessment.

Stud Health Technol Inform

Division of Medical Information Sciences, Geneva University Hospitals, Geneva, Switzerland.

Published: August 2024

Electrocardiogram (ECG) is one of the reference cardiovascular diagnostic exams. However, the ECG signal is very prone to being distorted through different sources of artifacts that can later interfere with the diagnostic. For this reason, signal quality assessment (SQA) methods that identify corrupted signals are critical to improve the robustness of automatic ECG diagnostic methods. This work presents a review and open-source implementation of different available indices for SQA as well as introducing an index that considers the ECG as a dynamical system. These indices are then used to develop machine learning models which evaluate the quality of the signals. The proposed index along the designed ML models are shown to improve SQA for ECG signals.

Download full-text PDF

Source
http://dx.doi.org/10.3233/SHTI240547DOI Listing

Publication Analysis

Top Keywords

ecg signal
8
signal quality
8
quality assessment
8
ecg
6
novel method
4
method python
4
python library
4
library ecg
4
assessment electrocardiogram
4
electrocardiogram ecg
4

Similar Publications

Background: The ability to non-invasively measure left atrial pressure would facilitate the identification of patients at risk of pulmonary congestion and guide proactive heart failure care. Wearable cardiac monitors, which record single-lead electrocardiogram data, provide information that can be leveraged to infer left atrial pressures.

Methods: We developed a deep neural network using single-lead electrocardiogram data to determine when the left atrial pressure is elevated.

View Article and Find Full Text PDF

We developed a deep learning-based extraction of electrocardiographic (ECG) waves from ballistocardiographic (BCG) signals and explored their use in R-R interval (RRI) estimation. Preprocessed BCG and reference ECG signals were inputted into the bidirectional long short-term memory network to train the model to minimize the loss function of the mean squared error between the predicted ECG (pECG) and genuine ECG signals. Using a dataset acquired with polyvinylidene fluoride and ECG sensors in different recumbent positions from 18 participants, we generated pECG signals from preprocessed BCG signals using the learned model and evaluated the RRI estimation performance by comparing the predicted RRI with the reference RRI obtained from the ECG signal using a leave-one-subject-out cross-validation scheme.

View Article and Find Full Text PDF

Pyridoxal-5-phosphate (PLP) enhances the synthesis of endogenous hydrogen sulfide, a potent regulator of cell metabolism. We used 24-month-old rats to investigate the PLP mitoprotective function in the aging heart. We demonstrated improvement of mitochondrial bioenergetic functions, inhibition of mPTP opening after PLP administration.

View Article and Find Full Text PDF

Passive cardiac monitoring has become synonymous with wearable technologies, necessitating patients to incorporate new devices into their daily routines. While this requirement may not be a burden for many, it is a constraint for individuals with chronic diseases who already have their daily routine. In this study, we introduce an innovative technology that harnesses the front-facing camera of smartphones to capture pulsatile signals discreetly when users engage in other activities on their device.

View Article and Find Full Text PDF

Stress classification with in-ear heartbeat sounds.

Comput Biol Med

December 2024

École de technologie supérieure, 1100 Notre-Dame St W, Montreal, H3C 1K3, Quebec, Canada; Centre for Interdisciplinary Research in Music Media and Technology (CIRMMT), 527 Rue Sherbrooke O #8, Montréal, QC H3A 1E3, Canada. Electronic address:

Background: Although stress plays a key role in tinnitus and decreased sound tolerance, conventional hearing devices used to manage these conditions are not currently capable of monitoring the wearer's stress level. The aim of this study was to assess the feasibility of stress monitoring with an in-ear device.

Method: In-ear heartbeat sounds and clinical-grade electrocardiography (ECG) signals were simultaneously recorded while 30 healthy young adults underwent a stress protocol.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!