A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of Perkin Elmer Amorphous Silicon Electronic Portal Imaging Device for Small Photon Field Dosimetry. | LitMetric

Background: Electronic portal imaging devices (EPIDs) are applied to measure the dose and verify patients' position.

Objective: The present study aims to evaluate the performance of EPID for measuring dosimetric parameters in small photon fields.

Material And Methods: In this experimental study, the output factors and beam profiles were obtained using the amorphous silicon (a-Si) EPID for square field sizes ranging from 1×1 to 10×10 cm at energies 6 and 18 mega-voltage (MV). For comparison, the dosimetric parameters were measured with the pinpoint, diode, and Semiflex dosimeters. Additionally, the Monaco treatment planning system was selected to calculate the output factors and beam profiles.

Results: There was a significant difference between the output factors measured using the EPID and that measured with the other dosimeters for field sizes lower than 8×8 cm. In the energy of 6 MV, the gamma passing rates (3%/3 mm) between EPID and diode profile were 98%, 98%, 95%, 94%, 93%, and 94% for 1×1, 2×2, 3×3, 4×4, 5×5, and 10×10 cm, respectively. The measured penumbra width with EPID was higher compared to that measured by the diode dosimeter for both energies.

Conclusion: The EPID can measure the dosimetric parameters in small photon fields, especially for beam profiles and penumbra measurements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11336047PMC
http://dx.doi.org/10.31661/jbpe.v0i0.2112-1445DOI Listing

Publication Analysis

Top Keywords

small photon
12
dosimetric parameters
12
output factors
12
amorphous silicon
8
electronic portal
8
portal imaging
8
parameters small
8
factors beam
8
beam profiles
8
field sizes
8