An efficient dual-domain deep learning network for sparse-view CT reconstruction.

Comput Methods Programs Biomed

Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, CH-1211 Geneva, Switzerland; Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, Netherlands; Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark; University Research and Innovation Center, Óbuda University, Budapest, Hungary. Electronic address:

Published: November 2024

AI Article Synopsis

  • Developed an efficient dual-domain deep-learning method for sparse-view CT reconstruction with minimal training parameters and comparable running time.
  • Designed two lightweight networks, Sino-Net and Img-Net, to restore projection and image signals, tested using clinical thoraco-abdominal CT data.
  • Results indicated the algorithm effectively reduced noise and artifacts, restored fine details, and improved overall image quality, showcasing its potential for practical clinical use.

Article Abstract

Background And Objective: We develop an efficient deep-learning based dual-domain reconstruction method for sparse-view CT reconstruction with small training parameters and comparable running time. We aim to investigate the model's capability and its clinical value by performing objective and subjective quality assessments using clinical CT projection data acquired on commercial scanners.

Methods: We designed two lightweight networks, namely Sino-Net and Img-Net, to restore the projection and image signal from the DD-Net reconstructed images in the projection and image domains, respectively. The proposed network has small training parameters and comparable running time among dual-domain based reconstruction networks and is easy to train (end-to-end). We prospectively collected clinical thoraco-abdominal CT projection data acquired on a Siemens Biograph 128 Edge CT scanner to train and validate the proposed network. Further, we quantitatively evaluated the CT Hounsfield unit (HU) values on 21 organs and anatomic structures, such as the liver, aorta, and ribcage. We also analyzed the noise properties and compared the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) of the reconstructed images. Besides, two radiologists conducted the subjective qualitative evaluation including the confidence and conspicuity of anatomic structures, and the overall image quality using a 1-5 likert scoring system.

Results: Objective and subjective evaluation showed that the proposed algorithm achieves competitive results in eliminating noise and artifacts, restoring fine structure details, and recovering edges and contours of anatomic structures using 384 views (1/6 sparse rate). The proposed method exhibited good computational cost performance on clinical projection data.

Conclusion: This work presents an efficient dual-domain learning network for sparse-view CT reconstruction on raw projection data from a commercial scanner. The study also provides insights for designing an organ-based image quality assessment pipeline for sparse-view reconstruction tasks, potentially benefiting organ-specific dose reduction by sparse-view imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2024.108376DOI Listing

Publication Analysis

Top Keywords

sparse-view reconstruction
16
projection data
12
anatomic structures
12
efficient dual-domain
8
learning network
8
network sparse-view
8
small training
8
training parameters
8
parameters comparable
8
comparable running
8

Similar Publications

Convergent-Diffusion Denoising Model for multi-scenario CT Image Reconstruction.

Comput Med Imaging Graph

January 2025

The Department of Computer and Data Science, Case Western Reserve University, Cleveland, OH, USA; The Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.

A generic and versatile CT Image Reconstruction (CTIR) scheme can efficiently mitigate imaging noise resulting from inherent physical limitations, substantially bolstering the dependability of CT imaging diagnostics across a wider spectrum of patient cases. Current CTIR techniques often concentrate on distinct areas such as Low-Dose CT denoising (LDCTD), Sparse-View CT reconstruction (SVCTR), and Metal Artifact Reduction (MAR). Nevertheless, due to the intricate nature of multi-scenario CTIR, these techniques frequently narrow their focus to specific tasks, resulting in limited generalization capabilities for diverse scenarios.

View Article and Find Full Text PDF

TD-STrans: Tri-domain sparse-view CT reconstruction based on sparse transformer.

Comput Methods Programs Biomed

December 2024

Department of Information and Communication Engineering, North University of China, Taiyuan 030051, China; The State Key Lab for Electronic Testing Technology, North University of China, Taiyuan 030051, China. Electronic address:

Background And Objective: Sparse-view computed tomography (CT) speeds up scanning and reduces radiation exposure in medical diagnosis. However, when the projection views are severely under-sampled, deep learning-based reconstruction methods often suffer from over-smoothing of the reconstructed images due to the lack of high-frequency information. To address this issue, we introduce frequency domain information into the popular projection-image domain reconstruction, proposing a Tri-Domain sparse-view CT reconstruction model based on Sparse Transformer (TD-STrans).

View Article and Find Full Text PDF

DDoCT: Morphology preserved dual-domain joint optimization for fast sparse-view low-dose CT imaging.

Med Image Anal

December 2024

School of Physics, Beihang University, Beijing, China; Hangzhou International Innovation Institute, Beihang University, Hangzhou, China; Tianmushan Laboratory, Hangzhou, China. Electronic address:

Computed tomography (CT) is continuously becoming a valuable diagnostic technique in clinical practice. However, the radiation dose exposure in the CT scanning process is a public health concern. Within medical diagnoses, mitigating the radiation risk to patients can be achieved by reducing the radiation dose through adjustments in tube current and/or the number of projections.

View Article and Find Full Text PDF

Photoacoustic tomography, a novel non-invasive imaging modality, combines the principles of optical and acoustic imaging for use in biomedical applications. In scenarios where photoacoustic signal acquisition is insufficient due to sparse-view sampling, conventional direct reconstruction methods significantly degrade image resolution and generate numerous artifacts. To mitigate these constraints, a novel sinogram-domain priors guided extremely sparse-view reconstruction method for photoacoustic tomography boosted by enhanced diffusion model is proposed.

View Article and Find Full Text PDF

Objective: There have been many advancements in deep unrolling methods for sparse-view computed tomography (SVCT) reconstruction. These methods combine model-based and deep learning-based reconstruction techniques, improving the interpretability and achieving significant results. However, they are often computationally expensive, particularly for clinical raw projection data with large sizes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!