Radiation mode-based microphone array: Experimental verification.

JASA Express Lett

Department of Mechanical Science and Engineering, Kogakuin University, 2665-1 Nakano-machi, Hachioji-shi, Tokyo 192-0015,

Published: August 2024

AI Article Synopsis

Article Abstract

The mouth of a speaker is generally close to the microphones of speech communication devices, such as headsets and phones, whereas noise sources are more distant from the microphones. Hence, near-field enhancement using microphone arrays is a promising strategy for noise suppression. This study deals with radiation mode-based microphone arrays and mainly focuses on experimentally validating the methodology. Because the radiation mode-based microphone array can be approximated as a gradient microphone, the difference between them and the advantage of the former over the latter are clarified by comparing the beampatterns.

Download full-text PDF

Source
http://dx.doi.org/10.1121/10.0028322DOI Listing

Publication Analysis

Top Keywords

radiation mode-based
12
mode-based microphone
12
microphone array
8
microphone arrays
8
microphone
5
array experimental
4
experimental verification
4
verification mouth
4
mouth speaker
4
speaker generally
4

Similar Publications

A wealth of details regarding an individual's state of health, like a person's respiratory and metabolic functioning, can be studied by analyzing the volatile molecules and atoms in human exhaled breath. Besides, the salinity of seawater is a crucial factor in understanding its characteristics because any variation in the salinity of seawater represents the variations in the hydrological, biological, and chemical distributions. In this paper, a symmetrical one-dimensional phononic structure is theoretically designed using two symmetrical crystals separated with a defective cavity.

View Article and Find Full Text PDF

Objective: The purpose of this study was to compare radiation dose reduction capability for accurate liver tumor measurements of a computer-aided volumetry (CAD v ) software for filtered back projection (FBP), hybrid-type iterative reconstruction (IR), mode-based iterative reconstruction (MBIR), and deep learning reconstruction (DLR) at a phantom study.

Methods: A commercially available anthropomorphic abdominal phantom was scanned five times with a 320-detector row CT at 600 mA, 400 mA, 200 mA, and 100 mA and reconstructed by four methods. Signal-to-noise ratios (SNRs) of all lesions within the arterial and portal-venous phase inserts were calculated, and SNR of the lesion phantom was compared with that of all reconstruction methods by means of Tukey's honestly significant difference (HSD) test.

View Article and Find Full Text PDF

Radiation mode-based microphone array: Experimental verification.

JASA Express Lett

August 2024

Department of Mechanical Science and Engineering, Kogakuin University, 2665-1 Nakano-machi, Hachioji-shi, Tokyo 192-0015,

The mouth of a speaker is generally close to the microphones of speech communication devices, such as headsets and phones, whereas noise sources are more distant from the microphones. Hence, near-field enhancement using microphone arrays is a promising strategy for noise suppression. This study deals with radiation mode-based microphone arrays and mainly focuses on experimentally validating the methodology.

View Article and Find Full Text PDF

The luminescent NbC MXene nanosheet-based whispering gallery mode-enhanced ECL strategy for miRNA-214 detection.

Talanta

November 2024

Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China. Electronic address:

MiRNA-214 can regulate the expression of their downstream target genes after post-transcriptional and are involved in the biological processes of triple negative breast cancer (TNBC). In this work, the small-sized luminescent NbC nanosheet-based whispering gallery mode-enhanced electrochemiluminescence (ECL) strategy was successfully constructed to detect miRNA-214 in TNBC. Firstly, we have synthesized small-sized luminescent NbC nanosheets from NbAlC MXene.

View Article and Find Full Text PDF

In order to improve the biological effect of proton therapy, the authors first propose a new method of boron-based proton-enhanced radiotherapy in a " ternary " radiotherapy mode, based on the existing sensitizing effect of proton radiotherapy: i.e, Boron-based mediators (B and B) induce the proton-hydrogen-boron fusion reaction of the low-energy protons arriving at the Bragg peak region of the tumor target area (p+B→3α) and thermal neutron capture (B+n→Li(0.84 MeV)+He(1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!