Background: The present study aimed to investigate whether proper sizing can improve the procedural and clinical outcomes of transcatheter aortic valve replacement (TAVR) with new-generation self-expanding valves (SEVs) and balloon-expandable valves (BEVs) for treating bicuspid aortic stenosis (BAS).

Methods: We retrospectively evaluated consecutive patients who underwent TAVR with Sapien 3 valves (Edwards Lifesciences, Irvine, CA) or Evolut R/PRO valves (Medtronic, Minneapolis, MN) for severe BAS from 2017 to 2022. The primary endpoints were device success rate and major adverse cardiac and cerebral events (MACCEs), including mortality, nonfatal myocardial infarction or disabling stroke, transcatheter heart valve failure, or clinically relevant valve thrombosis during follow-up. Our team used a complementary approach of supraannular sizing in addition to the conventional annular sizing method (Wei's method) to guide the TAVR procedures.

Results: We recruited a total of 75 consecutive patients, of whom 43 (57%) were treated with BEVs from October 2017 to June 2021, and 32 (43%) were treated with SEVs from July 2021 to December 2022. Device success was similar between the BEV and SEV groups (93% vs 94%; p > 0.99), and no cases of annular rupture occurred in either group. Similar rates of moderate-to-severe paravalvular leak were observed in the BEV and SEV groups (5% vs 6%, p > 0.99). At a median follow-up of 464 days, the MACCE rates were comparable between the two groups. In multivariate analysis, the presence of previous percutaneous coronary interventions (hazard ratio: 5.43; p = 0.039) and New York Heart Association functional class III/IV heart failure at 30 days of follow-up after TAVR (hazard ratio: 9.90; p = 0.037) were independently associated with long-term MACCEs.

Conclusion: Our results demonstrated comparable efficacy and safety for BAS patients undergoing TAVR using either BEVs or SEVs when using Wei's sizing method.

Download full-text PDF

Source
http://dx.doi.org/10.1097/JCMA.0000000000001155DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
sizing method
12
comparable efficacy
8
efficacy safety
8
bicuspid aortic
8
patients undergoing
8
transcatheter aortic
8
valve replacement
8
self-expanding valves
8
wei's sizing
8

Similar Publications

Background: Despite advancements in valve implantation devices, vascular access complications (VAC) remain a significant cause of morbidity and mortality for those undergoing transcatheter aortic valve replacement (TAVR). We describe pre-operative imaging analysis of the aortoiliac and femoral arterial beds using the TransAtlantic intersociety consensus (TASC) score, ilio-femoral tortuosity, and procedural characteristics to identify anatomic risk factors predictive of VAC in TAVR.

Methods: Consecutive patients undergoing TAVR from 2012 to 2022 at a single North Dakota hospital were retrospectively reviewed.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve replacement (TAVR) is a well-established treatment option for patients with severe aortic valve stenosis; however, clinical valve thrombosis is a major challenge.

Case Summary: A 92-year-old woman underwent TAVR for severe aortic stenosis. One month later, the patient developed acute heart failure.

View Article and Find Full Text PDF

We report a 75-year-old female with a history of two heart operations: aortic valve replacement (St. Jude Medical 21 mm) at the age of 44 years for severe rheumatic aortic stenosis and mitral valve replacement (Carbomedics 29 mm) at the age of 51 years for rheumatic mitral regurgitation. Decades later, she presented with exertional dyspnea.

View Article and Find Full Text PDF

Introduction The study aimed to retrospectively evaluate the early patient outcome and left ventricular function after mitral valve replacement with a tilting disc valve and total preservation. Patients and methods This retrospective observational study includes patients who underwent mitral valve replacement using a tilting disc valve with total preservation of mitral valvular and subvalvular apparatus from July 2021 to August 2022 at a single center. Results The data were reviewed retrospectively for age, sex, comorbidities, operating time, aortic cross-clamp time, cardiopulmonary bypass time, preoperative and postoperative left ventricular ejection fraction, mean gradient across the mitral valve, left ventricular diameter, left atrial size, atrial fibrillation, complications, mortality, and early patient outcome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!