Stochastic reaction-diffusion models are employed to represent many complex physical, biological, societal, and ecological systems. The macroscopic reaction rates describing the large-scale, long-time kinetics in such systems are effective, scale-dependent renormalized parameters that need to be either measured experimentally or computed by means of a microscopic model. In a Monte Carlo simulation of stochastic reaction-diffusion systems, microscopic probabilities for specific events to happen serve as the input control parameters. To match the results of any computer simulation to observations or experiments carried out on the macroscale, a mapping is required between the microscopic probabilities that define the Monte Carlo algorithm and the macroscopic reaction rates that are experimentally measured. Finding the functional dependence of emergent macroscopic rates on the microscopic probabilities (subject to specific rules of interaction) is a very difficult problem, and there is currently no systematic, accurate analytical way to achieve this goal. Therefore, we introduce a straightforward numerical method of using lattice Monte Carlo simulations to evaluate the macroscopic reaction rates by directly obtaining the count statistics of how many events occur per simulation time step. Our technique is first tested on well-understood fundamental examples, namely, restricted birth processes, diffusion-limited two-particle coagulation, and two-species pair annihilation kinetics. Next we utilize the thus gained experience to investigate how the microscopic algorithmic probabilities become coarse-grained into effective macroscopic rates in more complex model systems such as the Lotka-Volterra model for predator-prey competition and coexistence, as well as the rock-paper-scissors or cyclic Lotka-Volterra model and its May-Leonard variant that capture population dynamics with cyclic dominance motifs. Thereby we achieve a more thorough and deeper understanding of coarse graining in spatially extended stochastic reaction-diffusion systems and the nontrivial relationships between the associated microscopic and macroscopic model parameters, with a focus on ecological systems. The proposed technique should generally provide a useful means to better fit Monte Carlo simulation results to experimental or observational data.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevE.110.014124 | DOI Listing |
Indian J Nucl Med
November 2024
Center for Research and Production of Radioisotopes, Dalat Nuclear Research Institute, Vietnam Atomic Energy Institute (VINATOM), Da Lat City, Lam Dong Province, Vietnam.
Aims: This study aimed to evaluate the principal technical characteristics of a well-type gas-filled ionization chamber dose calibrator used in measuring radiopharmaceutical activity, namely accuracy, repeatability, and linearity. Furthermore, this work also explored the correlation between the device's response and the position and volume of the radiopharmaceutical I-131.
Materials And Methods: Experimental measurements were conducted on the ATOMLAB 500 dose calibrator using NIST traceable Cs-137 source to determine the accuracy and repeatability.
Sci Rep
January 2025
College of Safety Science and Engineering, Liaoning Technical University, Fuxin, 123000, Liaoning, China.
The abandoned coal in goaf will adsorb the gases ethylene (CH) and acetylene (CH) produced by coal oxidation, which makes the concentration data of the indicator gas inaccurate. Therefore, the adsorption law of coal and CH and CH gas is explored. The macromolecular structure model of coal was established and optimized by simulation, and the gas adsorption process was simulated by means of grand canonical Monte Carlo method.
View Article and Find Full Text PDFJ Phys Chem B
January 2025
Department of Chemical Engineering, IIT Gandhinagar, Gandhinagar, Gujarat 382055, India.
We compare the structures of polymer globules, composed of flexible polymer chains, with liquid droplets made of nonbonded monomers of the same polymer in poor solvents. This comparison is performed in three different poor solvents, with and without the addition of cosolvents. Molecular dynamics simulations are used to analyze the properties of the polymer globules, while semigrand canonical Monte Carlo simulations are used to form metastable liquid droplets of nonbonded monomers through homogeneous nucleation in the same solvents.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Radiation Oncology, Inha University Hospital, Incheon, Republic of Korea.
Background: High-dose-rate (HDR) brachytherapy using Iridium-192 as a radiation source is widely employed in cancer treatment to deliver concentrated radiation doses while minimizing normal tissue exposure. In this treatment, the precision with which the sealed radioisotope source is delivered significantly impacts clinical outcomes.
Purpose: This study aims to evaluate the feasibility of a new four-dimensional (4D) in vivo source tracking and treatment verification system for HDR brachytherapy using a patient-specific approach.
J Dairy Sci
January 2025
The Roslin Institute and Royal (Dick) School of Veterinary Studies, University of Edinburgh, Midlothian EH25 9RG, United Kingdom. Electronic address:
This study investigated the genetics of bovine tuberculosis (bTB) infectivity in Holstein-Friesian dairy cows using British national data. The analyses included cows with recorded sires from herds affected by bTB outbreaks between 2000 and 2022. Animals were considered bTB-positive if they reacted positively to the skin test and/or had positive post-mortem findings.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!