AI Article Synopsis

  • Acute Compartment Syndrome (ACS) is a serious condition caused by high pressure within muscle compartments, traditionally diagnosed using a needle method, which can be difficult and slow, prompting exploration of Shear Wave Ultrasound Elastography (SWE) as a faster, less invasive alternative.
  • A study with 32 turkeys tested the correlation between SWE readings and intra-muscle-compartment pressure by gradually increasing pressure in the muscly while measuring SWE values, muscle function, and gait over time.
  • Results showed a strong correlation (R2 = 0.91) between SWE values and actual pressure, with significant changes in muscle function and histological damage observed in groups subjected to higher pressure for extended periods.

Article Abstract

Introduction: Acute Compartment Syndrome (ACS) is a severe trauma caused by elevated intra-muscle-compartment pressure (ICP). The current standard method for diagnosis is to insert a needle into the muscle sterilely under anesthesia. However, to secure the environment is sometimes not easy and leads to delays in diagnosis. Recently, we have focused on shear wave ultrasound elastography (SWE) as an alternative, which can be done concisely in unclean environment and without anesthesia. We would like to report the usefulness of SWE for ACS diagnosis using 2-pedal walking turkey model recently developed in our lab.

Materials And Methods: A total of 32 1-year-old Bourbon turkeys were used. 5% solution of chicken albumin was infused continuously into the tibialis cranialis (TC) muscle using IV pump. The ICP was increased stepwise from 0 to 50 mmHg. During the rising of ICP, the correlation between values of SWE (kPa) and ICP (mmHg) was measured. After the ICP reached 50 mmHg, half of the turkeys were maintained at this pressure for 2 hours and the rest for 6 hours. After infusion, a fasciotomy was performed on the half turkey. Half of the turkeys were euthanized after 2 weeks and the rest after 6 weeks. SWE of TC muscle and walking gait data on turkeys using a portable walkway system were measured weekly until euthanasia. At euthanasia, isometric tetanic muscle force (ITF) tests to TC muscle and histological evaluations were performed.

Results: SWE value (kPa) was highly significantly correlated to the actual ICP (mmHg) (R2 = 0.91). Stance of ACS side leg were significantly extended, and swing of the control side shortened from the second to the third week after ACS in the 6 hours infusion-no-fasciotomy group (P < 0.05*). ITF was significantly reduced mainly in the 6 hours infusion group (P < 0.05*). Histological evaluation revealed that in the 6 hours infusion and 6 weeks survival group, both the muscle fiber and intercellular distances were significantly expanded (P < 0.05).

Conclusion: SWE seems to be a substitute measure of ICP in diagnosing ACS. With regard to our in vivo ACS model using turkey, survival at 50 mmHg ICP for 6 hours and 6 weeks post ACS would be an appropriate situation.

Download full-text PDF

Source
http://dx.doi.org/10.1093/milmed/usae211DOI Listing

Publication Analysis

Top Keywords

shear wave
8
acute compartment
8
compartment syndrome
8
turkey model
8
swe kpa
8
icp mmhg
8
half turkeys
8
icp
6
muscle
5
swe
5