Background: The difficulty of suturing perfect anastomoses in limited-access conditions prevents the transition of traditional coronary artery bypass grafting (CABG) to sternal-sparing approaches, even in the robotic era. Automated coronary anastomotic connector technologies may address these difficulties, but to date, none have achieved broad adoption. Besides versatility, ease-of-use and cost-effectiveness, the key performance parameter of such technology is anastomotic patency. In this meta-analysis, we aim to evaluate published connector devices by examining their patency outcomes in distal anastomoses.
Methods: The literature was systematically searched for studies comparing the angiographic patency of connector constructed coronary anastomoses to handsewn (HS) connections in adult patients undergoing CABG. The primary outcome was anastomosis patency across early (<30 days), mid-term (30 days to 1 year) and long-term (>1 year) follow-up. Random-effects meta-analyses were employed to analyze and compare patency using pooled risk ratios (RR) with 95% confidence intervals (CI).
Results: The search yielded 14 studies concerning eight connector devices. In 4,311 patients, a total of 4,328 anastomoses were constructed, 674 with connector devices and 3,654 with a HS technique. The pooled device patency over all timeframes was non-inferior to the HS technique (RR 0.90, 95% CI: 0.56-1.44). Technologies having a relatively large blood-exposed non-intimal surface area (BENIS, >15 mm) performed acceptably when applied to large target vessels [>2.0-2.5 mm inner diameter (ID)]. A tiny anastomotic orifice area (AOA, < ca. 4 mm) appeared to adversely affect results. Technologies realizing a generous AOA in combination with a limited BENIS showed superior results and applicability by performing well across the entire range of target coronary artery diameters (>1.0-1.5 mm ID).
Conclusions: The overall results suggest that connectors yield at least non-inferior anastomosis patency outcomes compared to HS techniques in all observed timeframes. Optimizing device characteristics like BENIS and AOA appear fundamental for broad applicability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11327408 | PMC |
http://dx.doi.org/10.21037/acs-2023-rcabg-0190 | DOI Listing |
In essence the resin-bonded fixed partial denture, or resin-bonded bridge, is an artificial tooth that is bonded to 1 or 2 abutment teeth. If the resin-bonded bridge is directly made with resin composite intra-orally, then the connector area is the weakest link. The alternative is to produce an indirect resin-bonded bridge in which a metal or ceramic frame spans the space between the abutments.
View Article and Find Full Text PDFJ Vasc Access
December 2024
Department of Medicine and Surgery, University of Milan-Bicocca, Monza, Italy.
Background: Needle-free connectors (NFCs) are recommended as closure systems for peripheral and central vascular catheters to reduce needlestick injuries and infections, while potentially reducing blood reflux. However, their performance in short-term dialysis catheters has never been evaluated. The aim of this study was to evaluate the backflow associated with two NFCs (Neutron™ and Tego™) compared to the standard closure.
View Article and Find Full Text PDFJ Vis Exp
November 2024
Department of Semiconductor Engineering, Gachon University; Department of Electronic Engineering, Gachon University;
The intramuscular electromyography (EMG) measurement method for experimental animals has been implemented in various ways. Among these methods, tethering cables to external measurement devices can restrict the movement of experimental animals, while implantable devices may cause unwanted side effects due to the constant presence of a device with considerable size and weight. To address these issues, we propose a low-cost, wireless, detachable EMG measurement system and experimental procedure.
View Article and Find Full Text PDFTalanta
March 2025
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic. Electronic address:
An off-the-shelf Agilent 7100 capillary electrophoresis (CE) instrument was employed for the automated processing and analysis of dried blood spots (DBSs) collected by Capitainer®B volumetric devices. Solutions for DBS elutions were transferred directly into CE vials through a separation capillary by the application of an auxiliary nitrogen gas connected to the external pressure line of the CE instrument. This allowed for liquid handling at pressures up to 15 bar and enabled the use of a single capillary for rapid DBS processing and efficient CE separations.
View Article and Find Full Text PDFCureus
October 2024
Department of Orthopaedic Surgery, Showa University, Tokyo, JPN.
Pyogenic spondylitis is generally managed conservatively; however, surgical intervention may be required depending on the patient's condition. In this report, we present a case of upper thoracic pyogenic spondylitis with a paravertebral abscess that was successfully treated using negative pressure wound therapy (NPWT) combined with a cranked rod construct and a minimally invasive posterior-only approach. This report was constructed based on previous medical records and imaging findings.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!