Background: Fluoroscopy is considered to be the gold standard and an essential requirement for catheter insertion. However, there is a paucity of data regarding the outcomes in ultrasound (USG)-guided insertion with and without fluoroscopy. We compared the complications of USG-guided tunneled dialysis catheter (TDC) insertion with and without fluoroscopy assistance.

Materials And Methods: This was a single-center randomized controlled trial (RCT) done in a tertiary hospital in North India. After screening 153 patients, 149 were enrolled: 87 were randomized into USG-guided insertion without fluoroscopy (group A) and 62 were randomized into USG-guided insertion with fluoroscopy (group B). All insertions were done in a dedicated procedure room by trained nephrologists. Outcomes were analyzed at baseline and at 1-month follow-up. Mechanical complications as well as infective and thrombotic complications were compared between both the groups.

Results: TDC insertion was successful (100%) in all the study participants ( = 149). One hundred twenty-nine catheters (86.5%) were inserted in the first attempt, 19 (12.5%) in the second attempt, and one catheter insertion required three attempts for insertion. The mean age of study participants was 43 years (±16.5), and males constituted 63% of the study cohort. Baseline laboratory characteristics of the two groups were comparable. The mean time of catheter insertion was 41.26 min (standard deviation [SD] 11.8) in group A and 47.74 min (SD 17.2) in group B ( = 0.007). The mean score of ease of catheter insertion, exit site bleed, infective and mechanical complications were not different between the two groups.

Conclusion: Our study concluded that fluoroscopy has no additional advantage in reducing mechanical, infective, or thrombotic complications. In experienced hands, USG-guided TDC insertion without fluoroscopy assistance is as good as the insertion done with fluoroscopy assistance, with a shorter procedure time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11326780PMC
http://dx.doi.org/10.25259/ijn_414_23DOI Listing

Publication Analysis

Top Keywords

insertion fluoroscopy
24
catheter insertion
20
insertion
13
usg-guided insertion
12
tdc insertion
12
dialysis catheter
8
fluoroscopy
8
randomized usg-guided
8
fluoroscopy group
8
mechanical complications
8

Similar Publications

3D-printed (3DP) drill guides have demonstrated significant potential to accurately guide pedicle screw insertion in spinal surgery. However, their role in the upper cervical spine is not well established. This review aimed to compare the efficacy and safety of 3DP drill guides to the conventional fluoroscopic-guided free-hand technique for pedicle screw insertion in the upper cervical spine.

View Article and Find Full Text PDF

Iliosacral screw osteosynthesis - state of the art.

Arch Orthop Trauma Surg

January 2025

Department of Orthopedics and Traumatology, University Medical Center Mainz, Mainz, Germany.

Iliosacral screw osteosynthesis is a widely recognized technique for stabilizing unstable posterior pelvic ring injuries, offering notable advantages, including enhanced mechanical stability, minimal invasiveness, reduced blood loss, and lower infection rates. However, the procedure presents technical challenges due to the complex anatomy of the sacrum and the proximity of critical neurovascular structures. While conventional fluoroscopy remains the primary method for intraoperative guidance, precise preoperative planning using multiplanar reconstructions and three-dimensional volume rendering is crucial for ensuring accurate placement of iliosacral or transsacral screws.

View Article and Find Full Text PDF

Background: An all-inside endoscopic flexor hallucis longus (FHL) tendon transfer is indicated for the treatment of chronic, full-thickness Achilles tendon defects. The aim of this procedure is to restore function of the gastrocnemius-soleus complex while avoiding the wound complications associated with open procedures.

Description: This procedure can be performed through 2 endoscopic portals, a posteromedial portal (the working portal) and a posterolateral portal (the visualization portal).

View Article and Find Full Text PDF

Purpose: Percutaneous nephrolithotomy (PCNL) as an established procedure for treatment of large kidney stones, can trigger life threatening complications. Postoperative hemorrhaging is one of the main complications of PCNL. This study investigates the effectiveness of balloon nephrostomy in reducing hemorrhage in the postoperative phase of PCNL.

View Article and Find Full Text PDF

TiRobot-assisted versus freehand femoral neck system placement in the treatment of femoral neck fractures: a systematic review and meta-analysis.

J Robot Surg

January 2025

The Third Ward of Orthopaedic Department, General Hospital of Ningxia Medical University, 804 Shengli South Street, Hui Autonomous Region, Yinchuan, Ningxia, 750004, People's Republic of China.

The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!