A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

True horizontal or gravity plane registration for transferring the maxillary scan into the virtual articulator by using a facial scanner without the need for an additional device. | LitMetric

True horizontal or gravity plane registration for transferring the maxillary scan into the virtual articulator by using a facial scanner without the need for an additional device.

J Prosthet Dent

Founder and Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle, Wash.

Published: August 2024

AI Article Synopsis

  • Various reference planes, such as the gravity reference plane, are used to transfer maxillary casts to analog articulators.
  • Traditional methods for recording the gravity reference plane involve additional devices, like extraoral scan bodies or printed reference tools.
  • This manuscript outlines a new technique that uses a facial scanner alone, aiming to streamline the process and decrease both clinical and lab time needed for digital data capture and maxillary scan integration.

Article Abstract

Different reference planes can be used to transfer the maxillary cast into the analog articulator, including the true horizontal or gravity reference plane. Different techniques have been described to record the gravity reference plane for transferring the maxillary scan into the virtual articulator by using facial scanning techniques. However, these digital facebow procedures require the use of an extraoral scan body system, printed reference device, or orientation reference board. This manuscript describes a technique for recording the gravity reference plane by using a facial scanner without the use of an additional device. This technique aims to reduce the clinical time needed to capture a patient's digital data and minimize the laboratory time needed to integrate the virtual patient and transfer the maxillary scan into the virtual articulator.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2024.06.029DOI Listing

Publication Analysis

Top Keywords

maxillary scan
12
scan virtual
12
virtual articulator
12
gravity reference
12
reference plane
12
true horizontal
8
horizontal gravity
8
transferring maxillary
8
articulator facial
8
facial scanner
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!