Accurate and precise measurement of hemoglobin concentration is critical for reliable estimations of anemia prevalence at the population level. When systematic and/or random error are introduced in hemoglobin measurement, estimates of anemia prevalence might be significantly erroneous and, hence, limit their usefulness. For decades, single-drop capillary blood has been the most common blood source used for the measurement of hemoglobin concentration in surveys, especially in low-income and middle-income countries. In this study, we highlight historical and emerging evidence that single-drop capillary blood introduces a high degree of random error (variability) to hemoglobin estimates, leading to less reliable estimates of anemia prevalence at the population level. At present, the best practice is to collect and use venous blood for measurement of hemoglobin with an automated hematology analyzer, following standard operating procedures and quality assurance measures. Where use of an automated analyzer is not possible, the analysis of venous blood in a point-of-care hemoglobinometer by trained phlebotomists or specimen collectors should be considered. A forthcoming systematic review will provide additional evidence on the accuracy and precision of single-drop capillary blood for hemoglobin assessment. In the meantime, we raise caution when using single-drop capillary blood for hemoglobin measurement as it can result in inaccurate hemoglobin estimates and less reliable anemia prevalence estimates.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11540862 | PMC |
http://dx.doi.org/10.1016/j.advnut.2024.100290 | DOI Listing |
Molecules
November 2024
Faculty of Biotechnology and Drug Development, University of Rijeka, 51000 Rijeka, Croatia.
Adenine nucleotides (ANs)-adenosine 5'-triphosphate (ATP), adenosine 5'-diphosphate (ADP), and adenosine 5'-monophosphate (AMP)-are essential for energy transfer and the supply of countless processes within cellular metabolism. Their concentrations can be expressed as adenylate energy charge (AEC), a measure of cellular metabolic energy that directly correlates with the homeostasis of the organism. AEC index has broad diagnostic potential, as reduced ATP levels are associated to various conditions, such as inflammatory diseases, metabolic disorders, and cancer.
View Article and Find Full Text PDFAllergy
November 2024
Toulouse Institute for Infectious and Inflammatory Diseases (Infinity), UMR 1291, INSERM, CNRS, University of Toulouse, Toulouse, France.
Background: Diagnosis of allergies is mostly based on the patient's clinical history and allergen provocation tests. Determination of specific IgE (sIgE) profiles can be performed to support allergy diagnosis. This is commonly done in vivo by the skin prick test or in vitro with automated systems.
View Article and Find Full Text PDFSoft Matter
October 2024
Department of Chemical Engineering, Imperial College London, London SW7 2AZ, UK.
Extensional flows of complex fluids play an important role in many industrial applications, such as spraying and atomisation, as well as microfluidic-based drop deposition. The dripping-on-substrate (DoS) technique is a conceptually-simple, but dynamically-complex, probe of the extensional rheology of low-viscosity, non-Newtonian fluids. It incorporates the capillary-driven thinning of a liquid bridge, produced by a single drop as it is slowly dispensed from a syringe pump onto a solid partially-wetting substrate.
View Article and Find Full Text PDFAdv Nutr
October 2024
Program Operations Unit, Nutrition International, Ottawa, Ontario, Canada. Electronic address:
Accurate and precise measurement of hemoglobin concentration is critical for reliable estimations of anemia prevalence at the population level. When systematic and/or random error are introduced in hemoglobin measurement, estimates of anemia prevalence might be significantly erroneous and, hence, limit their usefulness. For decades, single-drop capillary blood has been the most common blood source used for the measurement of hemoglobin concentration in surveys, especially in low-income and middle-income countries.
View Article and Find Full Text PDFLangmuir
July 2024
School of Manufacture Science and Engineering, Key Laboratory of Testing Technology for Manufacturing Process, Ministry of Education, Southwest University of Science and Technology, Mianyang 621010, P. R. China.
Controlling the spontaneous directional transport of droplets plays an important role in the application of microchemical reactions and microdroplet detection. Although the relevant technologies have been widely studied, the existing spontaneous droplet transport strategies still face problems of complex structure, single function, and poor flexibility. Inspired by the spontaneous droplet transport strategy in nature, an asymmetric wettability surface with microcone channels (AWS-MC) is prepared on a flexible fabric by combining surface modification and femtosecond laser manufacturing technology.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!