Sickle cell diseases (SCD) are the most common genetic disorders with significant morbidity and mortality worldwide, including in India. The high prevalence of this disorder in many geographical regions calls for the use of a point-of-care rapid diagnostic test (RDT) for early screening and management of the diagnosed cases to reduce the allied clinical severity. In view of this, the present study was undertaken for the validation of a point-of-care RDT kit (SICKLECHECKTM) for the screening of SCD. This validation and diagnostic accuracy study was conducted among the cases advised for screening of SCD. For validation, all the recruited cases were investigated for both the SICKLECHECKTM RDT kit and HPLC (Variant-II) considering HPLC as a gold standard. A total of 400 cases were screened for both tests. For the presence and absence of sickle cell hemoglobin in the samples, SICKLECHECKTM RDT kit results showed a sensitivity and specificity of 99.39% and 98.73% respectively with references to HPLC findings. For the detection of the 'AS' pattern, the SICKLECHECKTM RDT kit has shown a sensitivity and specificity of 99.07% and 98.81% respectively. For the detection of the 'SS' pattern, the SICKLECHECKTM RDT kit has shown a sensitivity and specificity of 97.92% and 100.0% respectively. Cases with β thalassemia trait, hemoglobin E trait, hemoglobin Lepore trait and trait for hereditary-persistence-of-fetal-hemoglobin (high HbF %) diagnosed in HPLC were resulted with 'AA' pattern in SICKLECHECKTM RDT kit. The high sensitivity and specificity of the SICKLECHECKTM RDT kit insist on its use as a point-of-care screening tool for SCD especially where there is a lack of laboratory facilities as well as in hospital-based set-up requiring immediate diagnosis and management of SCD. However, for further confirmation, the samples should be analyzed with other gold standard techniques like HPLC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11329129PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0309045PLOS

Publication Analysis

Top Keywords

rdt kit
28
sicklechecktm rdt
24
sensitivity specificity
16
sickle cell
12
kit sensitivity
12
pattern sicklechecktm
12
point-of-care rapid
8
rapid diagnostic
8
diagnostic test
8
kit
8

Similar Publications

Cholera rapid diagnostic tests (RDTs) are vulnerable to virulent bacteriophage predation. We hypothesized that an enhanced cholera RDT that detects the common virulent bacteriophage ICP1 might serve as a proxy for pathogen detection. We previously developed a monoclonal antibody (mAb) to the ICP1 major capsid protein.

View Article and Find Full Text PDF

Novel isothermal nucleic acid amplification method for detecting malaria parasites.

Appl Microbiol Biotechnol

December 2024

Laboratório de Pesquisa em Malária, Instituto Oswaldo Cruz (IOC), Fundação Oswaldo Cruz (Fiocruz), Rio de Janeiro, Brazil.

Article Synopsis
  • Malaria, caused by Plasmodium spp. and transmitted by Anopheles mosquitoes, remains a significant global health threat, with 249 million cases and 608,000 deaths reported in 2022.
  • The study evaluated the GENEYE® ERA Plasmodium detection kit for rapid and accurate malaria diagnosis in the Brazilian Amazon, comparing it with traditional methods like microscopy and rapid diagnostic tests (RDT).
  • Results indicated that the ERA test demonstrated 100% sensitivity alongside qPCR, while microscopy and RDT had lower sensitivity, highlighting the need for improved diagnostic tools in malaria-endemic regions.
View Article and Find Full Text PDF

The rapid diagnosis of coronavirus disease 2019 (COVID-19) is critical for comprehensive public health response strategies, and self-testing with antigen rapid diagnostic tests (Ag-RDTs) presents opportunities to test in hard-to-reach communities. Therefore, we evaluated the acceptability, feasibility, and uptake of Ag-RDT self-testing at the community level in Tanzania. From June to October 2022, symptomatic individuals or those with recent contact with a known or suspected COVID-19 patient were offered assisted testing and self-testing within mining communities and at transport hubs.

View Article and Find Full Text PDF
Article Synopsis
  • Typhoid fever is a major public health issue in Ghana, leading to improper antibiotic use, yet there's limited data on the reliability of the Typhidot rapid diagnostic test for confirming the disease.
  • A study conducted in Southern Ghana with 258 participants evaluated the Typhidot test against blood and stool cultures, finding it had low sensitivity (35% for blood) and specificity (45% for stool), indicating it may not accurately diagnose typhoid fever.
  • The research also revealed that most Salmonella enterica isolates came from stool samples, highlighting a chance to address typhoid transmission during acute infections, but emphasizes the need for better diagnostic methods to prevent antibiotic misuse.
View Article and Find Full Text PDF

Background: False negative rapid diagnostic tests (RDTs) accruing to the non-detection of Plasmodium falciparum histidine-rich protein 2/3 (Pfhrp2/3) is threatening the diagnosis and management of malaria. Although regular monitoring is necessary to gauge the level of efficacy of the tool, studies in Cameroon remain limited. This study assessed Plasmodium spp.