A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simple and Ultrasensitive Nanozyme-Linked Immunosorbent Assay for SARS-CoV-2 Detection on a Syringe-Driven Filtration Device. | LitMetric

This work proposed a simple and ultrasensitive nanozyme-based immunoassay on a filtration device for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid protein (NP). Gold core porous platinum shell nanoparticles (Au@Pt NPs) were synthesized with high catalytic activity to oxidize 3,3',5,5'-tetramethylbenzidine, leading to an oblivious color change. The filtration device was designed based on the size difference of magnetic beads, filter membrane pore, and Au@Pt NPs. A simple, rapid, and consistent washing procedure can be performed with the help of a plastic syringe. This detection method could realize the quantitative detection of SARS-CoV-2 NP within 80 min for point-of-care needs. The limit of detection for the SARS-CoV-2 antigen was 0.01 ng/mL in buffer. The coefficients of variation of the assay were 1.78% for 10 ng/mL SARS-CoV-2 antigen, 2.03% for 1 ng/mL SARS-CoV-2 antigen, and 2.34% for the negative sample, respectively. The specificity of the detection platform was verified by the detection of various respiratory viruses. This simple and effective detection system was expected to promote substantial progress in the development and application of virus immunodetection technology.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.4c08787DOI Listing

Publication Analysis

Top Keywords

filtration device
12
sars-cov-2 antigen
12
simple ultrasensitive
8
detection
8
au@pt nps
8
detection sars-cov-2
8
ng/ml sars-cov-2
8
sars-cov-2
6
simple
4
ultrasensitive nanozyme-linked
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!