A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Implementation and Evaluation of a Gait Training Assistant for the Use of Crutches: Usability Study. | LitMetric

Background: Surgical procedures on the lower extremities often require weight-bearing on crutches as part of the rehabilitation process. Orthopedic elective procedures enable patients to learn the correct use of crutches in a controlled preoperative setting. Digital assistance systems can safely circumvent a shortage of skilled staff and any contact restrictions that may be necessary.

Objective: The usability of a newly developed gait training assistant (GTA) for the use of crutches will be evaluated. An intervention group trained to use crutches by the digital trainer will be compared with a control group trained to use crutches conventionally by a physiotherapist.

Methods: As part of the development and implementation of a novel GTA, 14 patients learned to walk with crutches by completing specific exercises while receiving live feedback. Their movements were detected by a depth sensor and evaluated in real time. Specific parameters (step length, synchronous movement, crutch angle, and crutch distance to the feet) were compared with a control group (n=14) trained to use crutches by physiotherapists. The intervention group was also assessed by a physiotherapist. At the end of the study, the patients completed questionnaires to evaluate the usability of the system (Brooke's System Usability Scale score) and patient satisfaction.

Results: All patients trained by the novel GTA were able to use crutches correctly. The intervention group showed significantly better values for crutch angle (mean -6.3°, SD 3.5° vs mean -12.4°, SD 4.5°; P<.001) and crutch position (mean 3.3, SD 5.1 cm vs mean -8.5, SD 4.9 cm; P=.02). Both groups reported that they felt confident in the use of crutches, were able to follow the instructions, and enjoyed the training. Even though the majority (12/14, 86%) preferred physical therapy over a purely digital approach, most participants enjoyed using the system (13/14, 93%) and were interested in trying out other digital assistants (11/14, 79%). The usability of the GTA was rated above average by the majority (9/14, 64%) of the patients.

Conclusions: The newly designed GTA is a safe method of teaching the use of crutches and is statistically superior to training by a physiotherapist. Even if patients prefer interaction with a physiotherapist over a purely digital approach, digital devices provide a safe and motivating opportunity to learn the essential locomotor skills for rehabilitation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11364940PMC
http://dx.doi.org/10.2196/51898DOI Listing

Publication Analysis

Top Keywords

intervention group
12
trained crutches
12
crutches
9
gait training
8
training assistant
8
gta crutches
8
group trained
8
compared control
8
control group
8
novel gta
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!