AI Article Synopsis

  • HA-coated femoral stems were developed to improve the stability and longevity of hip implants in total hip arthroplasty (THA).
  • A study followed 326 patients for an average of 9.39 years, using various clinical and radiological measures to assess outcomes, with a focus on stem survival.
  • Results showed 100% survival from aseptic loosening and excellent patient-reported outcomes, confirming effective osseointegration of the implants.

Article Abstract

Background: Hydroxyapatite (HA) coated femoral stems were introduced to enhance the biological fixation at the implant-bone interface, aiming to increase the longevity and survival of the prostheses. We aimed to assess the long-term outcomes of an HA ceramic (HAC) coated stem in primary total hip arthroplasty (THA), assess the stem survival, and clinically evaluate the patients using patient-reported outcome measures (PROMs) and radiological evaluation of stem osseointegration.

Patients And Methods: This was a prospective evaluation of a retrospective cohort of 385 patients (442 hips) who underwent primary THA between June 2008 and December 2018. The mean age was 63.83 years (range, 30-82 years). During the follow-up duration, 23 patients died, and 36 patients (38 hips) were lost to follow-up. Prospective data collected for 326 patients (381 hips) was used to evaluate stem survival with the Kaplan-Meier method using aseptic loosening or any revision as the endpoint. Clinical evaluation was done using the EuroQol five-dimension (EQ-5D) scoring system and PROMs using the Oxford Hip Score (OHS) and Merle D'Aubigne Postel (MDP) score. Radiological assessments were performed using the Engh radiological criteria for stem osteointegration.

Results: The mean follow-up duration was 9.39 years (range, 4-14.5 years). The survival of the HAC-coated femoral stem was 100% (95% confidence interval [CI], 96.7-100%) at 14 years with aseptic loosening as the endpoint, and 98.9% (CI, 96.7-100%) at 14 years with stem revision for any reason as the endpoint. The mean OHS was 44.5 (range, 30-48), and the mean MDP score was 15.87 (range, 10-18). Radiological evaluations showed full osseointegration of all stems.

Conclusion: This HAC-coated femoral stem has shown excellent survivorship, functional outcomes, and full osseointegration at the final follow-up.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11325862PMC
http://dx.doi.org/10.1051/sicotj/2024026DOI Listing

Publication Analysis

Top Keywords

femoral stem
12
stem
9
stem primary
8
primary total
8
total hip
8
hip arthroplasty
8
excellent survivorship
8
stem survival
8
years range
8
follow-up duration
8

Similar Publications

Background: Improvements in cementless total hip arthroplasty have been directed at optimizing osseointegration of the femoral implant to reduce aseptic loosening rates. Stem design plays a critical role in the performance of these implants. Given the increase in new stem designs and the creation of an updated classification system, improved understanding of the outcomes of each stem type is warranted.

View Article and Find Full Text PDF

Proximal femoral fractures are particularly common in older adults, and cases requiring conversion to total hip arthroplasty may arise because of treatment failure or osteoarthritis. Fractures around the distal screw removal holes can be problematic. This study aimed to analyze the relationship between stem length and femoral stress distribution to determine the optimal stem length.

View Article and Find Full Text PDF

Large bone defects are still a persistent challenge in orthopedics. The availability limitations and associated complications of autologous and allogeneic bone have prompted an increasing reliance on tissue engineering and regenerative medicine. In this study, we developed an injectable scaffold combining an acellular extracellular periosteal matrix hydrogel with poly(d,l-lactate--glycol-acetate) microspheres loaded with the E7 peptide and miR217 (miR217/E7@MP-GEL).

View Article and Find Full Text PDF

Implant failure of the Compress prosthesis: a case report.

J Med Case Rep

January 2025

Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya University Hospital, 65 Tsurumai, Showa, Nagoya, Aichi, 466-8550, Japan.

Background: The Compress is designed to achieve bone formation and stability by applying pressure at the bone-implant interface, minimizing the likelihood of aseptic loosening, which is a complication of stem implants. Herein, we report two cases of implant failure using the Compress.

Case Presentation: Case 1 describes a 36 year-old Japanese man who underwent extraarticular tumor resection, Compress arthroplasty, and reconstruction with a gastrocnemius flap after preoperative chemotherapy for a secondary malignant giant cell tumor in the right distal femur.

View Article and Find Full Text PDF

Purpose: Proximal femoral fractures are common within the elderly population and are associated with a high risk of mortality and reduced quality of life. Hemiarthroplasty or osteosynthesis (extramedullary or intramedullary) is the primary treatment option for these fractures. However, within this fragile patient population many comorbidities, among others dementia, are seen.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!