A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Unmasking anxiety: a head-to-head comparison of open and closed masks in head and neck cancer radiotherapy. | LitMetric

Background: Facemasks accurately immobilise patients with head and neck cancer (HNC) receiving radiotherapy (RT). However, such masks are associated with treatment related distress, a prognostic factor for poorer survival. Open masks offer increased comfort and patient satisfaction. We investigated whether open masks could immobilise patients without affecting treatment accuracy.

Materials And Methods: Over an 18-month period, all HNC RT patients with anxiety were offered open masks. Once 30 patients had completed treatment, set-up data was compared to patients in closed masks. The mean displacement and one-dimensional standard deviations (SD) of the mean, systematic and random set-up errors were calculated for translational directions: anterior-posterior (), superior-inferior (), medial-lateral (). The mean and SD of the mean was calculated for rotational displacements. Mann-Whitney U was used to determine any significant differences between set-up data.

Results: Sixty patients were included (30 open & 30 closed masks). There was no statistically significant difference found in the x (p = 0.701), y (p = 0.246) or z (p = 0.535) direction for the SD of the mean displacements between both masks. No statistically significant difference was found in the SD of means for rotational displacements. The calculated planning target volume (PTV) margin requirements were minimally less for the closed masks 3.5, 2.6, and 2.7 mm (x, y, z, respectively) versus 4.2, 3.2, and 3.7 mm, respectively, for open masks.

Conclusion: Our study demonstrates that open masks maintain accuracy at levels comparable to closed masks in patients with anxiety. The minor difference in the calculated PTV margin could be rectified with daily on-line imaging or surface guided imaging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11321773PMC
http://dx.doi.org/10.5603/rpor.99905DOI Listing

Publication Analysis

Top Keywords

closed masks
20
open masks
16
masks
11
open closed
8
head neck
8
neck cancer
8
immobilise patients
8
patients anxiety
8
masks patients
8
rotational displacements
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!