Background: Salmonella, a foodborne pathogen poses significant threats to food safety and human health. Immunochromatographic (ICTS) sensors have gained popularity in the field of food safety due to their convenience, speed, and cost-effectiveness. However, most existing ICTS sensors rely on antibody sandwich structures which are limited by their dependence on high-quality paired antibodies and restricted sensitivity. For the first time, we combined multi-line ICTS strips with fluorescent bacterial probes to develop a label-free multi-line immunochromatographic sensor capable of detecting broad-spectrum Salmonella. Salmonella was labeled with the aggregation-induced luminescence material TCBPE, resulting in its transformation into a green fluorescent probe.

Results: Using this sensor, we successfully detected Salmonella typhimurium within the concentration range of 10-10 CFU/mL with a visual detection limit of 6.0 × 10 CFU/mL. Compared to single-line sensors, our multi-line sensor exhibited significantly improved fluorescence intensity resulting in enhanced detection sensitivity by 50 %. Furthermore, our developed multi-line ICTS sensor demonstrated successful detection of 18 different strains of Salmonella without any cross-reaction observed with 5 common foodborne pathogens tested. The applicability and reliability were validated using milk samples, cabbage juice samples as well and drinking water samples suggesting its potential for rapid and accurate detection of Salmonella in real-world scenarios across both the food industry and clinical settings.

Significance: In this experiment, we developed a TCBPE-based multiline immunochromatographic sensor. Specifically, Salmonella was labeled with the aggregation-induced luminescence material TCBPE, resulting in its transformation into a green fluorescent probe. Through the multi-line analysis system, the detection sensitivity and accuracy of the sensor are improved. In brief, the sensor does not require complex antibody labeling and paired antibodies, and only one antibody is needed to complete the detection process.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2024.343006DOI Listing

Publication Analysis

Top Keywords

immunochromatographic sensor
12
label-free multi-line
8
multi-line immunochromatographic
8
sensor
8
salmonella
8
detection salmonella
8
food safety
8
icts sensors
8
paired antibodies
8
multi-line icts
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!