Previous research suggests that noise sensitivity is related to inefficient auditory processing that might increase the mental load of noise and affect noise evaluation. This assumption was tested in an experiment using a dual-task paradigm with a visual primary task and an auditory secondary task. Results showed that participants' noise sensitivity was positively correlated with mental effort. Furthermore, mental effort mediated the effect of noise sensitivity on loudness and unpleasantness ratings. The results thus support the idea that noise sensitivity is related to increased mental effort and difficulties in filtering auditory information and that situational factors should be considered.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/10.0028201 | DOI Listing |
iScience
January 2025
Department of Electrical and Computering Engineering, Binghamton University, Binghamton, NY 13902, USA.
Our recent research on type-I quadrature parity-time (PT) symmetry, utilizing an open twin-beam system, not only enables observing genuine quantum photonic PT symmetry amid phase-sensitive amplification (PSA) and loss in the presence of Langevin noise but also reveals an additional classical-to-quantum (C2Q) transition in noise fluctuations. In contrast to the previous setup, our exploration of an alternative system assuming no loss involves a type-II PSA-only scheme. This scheme facilitates dual opposing quadrature-PT symmetry, offering a comprehensive and complementary comprehension of C2Q transitions and PT-enhanced quantum sensing with optimal performance in the symmetry unbroken region.
View Article and Find Full Text PDFTrends Hear
January 2025
Key Laboratory of Noise and Vibration Research, Institute of Acoustics, Chinese Academy of Sciences, Beijing, China.
Wide dynamic range compression (WDRC) and noise reduction both play important roles in hearing aids. WDRC provides level-dependent amplification so that the level of sound produced by the hearing aid falls between the hearing threshold and the highest comfortable level of the listener, while noise reduction reduces ambient noise with the goal of improving intelligibility and listening comfort and reducing effort. In most current hearing aids, noise reduction and WDRC are implemented sequentially, but this may lead to distortion of the amplitude modulation patterns of both the speech and the noise.
View Article and Find Full Text PDFAnal Chem
January 2025
School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
A highly sensitive trace gas sensing system based on carbon black absorption enhanced photoacoustic (PA) spectroscopy (PAS) is reported. A carbon black sheet and a fiber-optic cantilever microphone (FOCM) are integrated to form a fiber-optic cantilever spectrophone (FOCS). The gas concentration is obtained by measuring the acoustic wave amplitude generated by the carbon black sheet, which absorbs the laser passing through the interest gas.
View Article and Find Full Text PDFSci Rep
January 2025
Imaging Department, Yantaishan Hospital, Yantai, China.
Noise-induced hearing loss (NIHL) is a common occupational condition. The aim of this study was to develop a classification model for NIHL on the basis of both functional magnetic resonance imaging (fMRI) and structural magnetic resonance imaging (sMRI) by applying machine learning methods. fMRI indices such as the amplitude of low-frequency fluctuation (ALFF), fractional amplitude of low-frequency fluctuation (fALFF), regional homogeneity (ReHo), degree of centrality (DC), and sMRI indices such as gray matter volume (GMV), white matter volume (WMV), and cortical thickness were extracted from each brain region.
View Article and Find Full Text PDFJ Cardiovasc Magn Reson
January 2025
Philips Healthcare, Beijing 100600, China.
Background: This study aims to identify optimal acceleration factors (AFs) for compressed sensing (CS) technology to enhance its clinical application for suspected coronary artery disease (CAD) in whole-heart non-contrast coronary magnetic resonance angiography (CMRA).
Methods: Two hundred and seventeen individuals with suspected CAD underwent whole-heart non-contrast CMRA on a 1.5-T CMR scanner with CS AFs of 2, 4, and 6 (CS2, CS4, and CS6).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!