Background: There is limited research on the intra-individual efficacy of ventricular pacing minimization algorithms developed by Biotronik-the Ventricular Pace Suppression algorithm (VpS) and the Intrinsic Rhythm Support plus algorithm (IRSplus) (BIOTRONIK SE & Co. KG, Berlin, Germany). We performed a randomized pilot trial that evaluated the efficacy of two algorithms in patients with symptomatic sinus node dysfunction (SND) who received a dual-chamber pacemaker.
Methods: The trial was conducted in 11 tertiary hospitals in South Korea. The patients were randomized to either the VpS or IRSplus algorithm group after a 3-month period of fixed atrioventricular (AV) delay. The primary outcome was the ventricular pacing percentage (Vp%) at each follow-up visit. The secondary outcomes were the occurrence of heart failure (HF) and atrial fibrillation (AF) during the study period.
Results: Data from 131 patients were analyzed. Initially, their average Vp% over 3 months with a fixed AV interval was 14.1 ± 19.4%. Patients were randomly assigned to VpS and IRSplus groups, with 66 and 65 in each. Algorithms reduced average Vp% to 4.0 ± 11.3% at 9 months and 6.7 ± 14.9% at 15 months. These algorithms were more effective for patients with paced AV delay (PAVD) ≤300 ms compared to those with PAVD >300 ms. Both algorithms were equally effective in reducing Vp%. Clinical AF or HF hospitalization was not observed during the study period.
Conclusion: The VpS and IRSplus algorithms are effective and safe in minimizing unnecessary ventricular pacing in patients with SND.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11317712 | PMC |
http://dx.doi.org/10.1002/joa3.13117 | DOI Listing |
Elife
December 2024
Department of Computer Science, University of Oxford, Oxford, United Kingdom.
Sudden death after myocardial infarction (MI) is associated with electrophysiological heterogeneities and ionic current remodelling. Low ejection fraction (EF) is used in risk stratification, but its mechanistic links with pro-arrhythmic heterogeneities are unknown. We aim to provide mechanistic explanations of clinical phenotypes in acute and chronic MI, from ionic current remodelling to ECG and EF, using human electromechanical modelling and simulation to augment experimental and clinical investigations.
View Article and Find Full Text PDFAm J Case Rep
December 2024
Department of Cardiac Pacing and Electrophysiology, Fortis Escorts Heart Institute (FEHI), New Delhi, India.
BACKGROUND Second-degree atrioventricular (AV) block is a frequently encountered conduction abnormality on surface electrocardiogram (ECG). However, it does not always imply a block at the AV nodal level. In rare cases, this block can occur below the bundle of His, within the infra-Hisian region of the His-Purkinje system.
View Article and Find Full Text PDFJ Med Case Rep
December 2024
Department of Cardiology and Vascular Medicine, Faculty of Medicine, Universitas Padjadjaran, Hasan Sadikin General Hospital, Bandung, Indonesia.
Background: This case highlights the management of concomitant acute myocarditis and congenital long QT syndrome with electrical storm and incessant Torsade de Pointes.
Case Presentation: An 18 years-old Southeast Asian para 1 abortus 0 (P1A0) postpartum patient with cesarean section owing to severe preeclampsia, acute lymphocytic myocarditis, and prolonged QT interval owing to long QT syndrome. She has incessant Torsade de Pointes treated with beta-blocker, lidocaine, overdrive pacing with a temporary transvenous pacemaker, left cardiac sympathetic denervation per video-assisted thoracoscopic surgery, and implantable cardioverter-defibrillator implantation.
Am Heart J
December 2024
Department of Cardiology, San Maurizio Regional Hospital, Bolzano, Italy.
Background: Cardiac resynchronization therapy (CRT) is a cornerstone treatment for heart failure, yet the optimal pacing mode remains uncertain. This study investigates the impact of DDDR (rate-adaptive atrial support) versus VDD pacing modes on functional capacity and echocardiographic outcomes in patients with CRT-defibrillators.
Methods: In a multicenter, double-blind, crossover trial, 26 sinus rhythm patients undergoing CRT-defibrillator implantation were randomized to DDDR at 60 beats-per-minute or VDD at 30 beats-per-minute.
Cardiol Res
December 2024
Department of Cardiology, Fukuoka University Hospital, Fukuoka, Japan.
An 83-year-old man underwent dual-chamber pacemaker placement for complete atrioventricular block at another hospital. The active-fixation ventricular lead was positioned on the free wall of the anterior right ventricle. Ventricular pacing failure occurred on the day after pacemaker implantation, and fluoroscopy revealed right ventricular (RV) lead perforation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!