AI Article Synopsis

  • The study aims to improve total hip arthroplasty (THA) stability by developing an AI algorithm that predicts impingement based on individual spinopelvic mechanics and patient characteristics.
  • Conducted across two centers with 157 adults, the research utilized robotic technology to assess impingement during specific movements and employed the Light Gradient-Boosting Machine (LGBM) for prediction analysis.
  • The results showed LGBM's prediction accuracy for impingement at 70.2%, with notable performance in estimating direction (85%) and type (72.9%), highlighting the potential of AI in enhancing THA outcomes.

Article Abstract

Aims: Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable gap in research utilizing artificial intelligence (AI). The objective of our pilot study was to evaluate the feasibility of developing an AI algorithm tailored to individual spinopelvic mechanics and patient phenotype for predicting impingement.

Methods: This international, multicentre prospective cohort study across two centres encompassed 157 adults undergoing primary robotic arm-assisted THA. Impingement during specific flexion and extension stances was identified using the virtual range of motion (ROM) tool of the robotic software. The primary AI model, the Light Gradient-Boosting Machine (LGBM), used tabular data to predict impingement presence, direction (flexion or extension), and type. A secondary model integrating tabular data with plain anteroposterior pelvis radiographs was evaluated to assess for any potential enhancement in prediction accuracy.

Results: We identified nine predictors from an analysis of baseline spinopelvic characteristics and surgical planning parameters. Using fivefold cross-validation, the LGBM achieved 70.2% impingement prediction accuracy. With impingement data, the LGBM estimated direction with 85% accuracy, while the support vector machine (SVM) determined impingement type with 72.9% accuracy. After integrating imaging data with a multilayer perceptron (tabular) and a convolutional neural network (radiograph), the LGBM's prediction was 68.1%. Both combined and LGBM-only had similar impingement direction prediction rates (around 84.5%).

Conclusion: This study is a pioneering effort in leveraging AI for impingement prediction in THA, utilizing a comprehensive, real-world clinical dataset. Our machine-learning algorithm demonstrated promising accuracy in predicting impingement, its type, and direction. While the addition of imaging data to our deep-learning algorithm did not boost accuracy, the potential for refined annotations, such as landmark markings, offers avenues for future enhancement. Prior to clinical integration, external validation and larger-scale testing of this algorithm are essential.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11322786PMC
http://dx.doi.org/10.1302/2633-1462.58.BJO-2024-0020.R1DOI Listing

Publication Analysis

Top Keywords

impingement
9
predict impingement
8
total hip
8
tailored individual
8
individual spinopelvic
8
flexion extension
8
tabular data
8
impingement prediction
8
impingement type
8
imaging data
8

Similar Publications

The dried capitulum of chrysanthemums is a traditional material in scented tea, and the kill-green process is a critical step in determining their quality. However, the changes in the physicochemical properties during kill-green and the mechanisms by which these changes affect drying characteristics, metabolic components, and aroma profiles remain unclear. Therefore, this study investigated the changes in water status, polyphenol oxidase and peroxidase activities, and microstructure during high-humidity air impingement kill-green (HHAIK) and steam kill-green (SK), and their effects on drying behavior, color, phytochemicals, and volatile profile of dried chrysanthemums.

View Article and Find Full Text PDF

The combination of hip arthroscopy and periacetabular osteotomy (PAO) has been proven safe and effective for addressing symptoms in patients with developmental dysplasia of the hip (DDH). As not every patient with dysplasia will require a hip arthroscopy to obtain desired clinical improvement in the setting of periacetabular osteotomy, a challenge is identifying which patients require adjacent procedures (either via arthroscopic or open) to fully treat their hip pathology. Even though labral repair is the most reported arthroscopic procedure in cases of hip dysplasia, I would suggest that labral treatment is the least likely helpful component of hip arthroscopy in these cases.

View Article and Find Full Text PDF

We report a rare case of a 29-year old woman presenting with abdominal pain, whose initial examination failed to identify intrauterine contraceptive device (IUCD) threads. IUCD migration was confirmed by CT scan and subsequent single-port laparoscopic retrieval alleviated her symptoms.

View Article and Find Full Text PDF

Purpose: To identify key molecular components within the femoroacetabular impingement hip and compare the findings between male and female patients across varying age groups.

Methods: All patients undergoing hip arthroscopy for femoroacetabular impingement syndrome (FAIS) without hip dysplasia were included. During hip arthroscopy, performed at University of Wisconsin Health, loose articular cartilage, excess synovium, damaged labral tissue, and minimal adipose tissue were debrided only as needed for visualization and tissue repair purposes and collected.

View Article and Find Full Text PDF

Simulated Cam Morphology of the Hip Changes Sacroiliac Motion During Hip Motion and Loading in a Cadaveric Model.

Arthrosc Sports Med Rehabil

December 2024

Department of Orthopedic Surgery and Sports Medicine, Mayo Clinic, Rochester, Minnesota, U.S.A.

Purpose: To determine the relationship between cam morphology of the hip and ipsilateral sacroiliac motion compared to the native hip in a cadaveric model.

Methods: A simulated cam state was created using a 3-dimensional printed cam secured to the head-neck junction of 5 cadaveric hips. Hips were studied using a computed tomography-based optic metrology system and a 6 degree-of-freedom robot to exert an internal rotation torque at 3 different torque levels (6 N-m, 12 N-m, 18 N-m).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!