Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Although the information obtained from in vivo proton magnetic resonance spectroscopy (H MRS) presents a complex-valued spectrum, spectral quantification generally employs linear combination model (LCM) fitting using the real spectrum alone. There is currently no known investigation comparing fit results obtained from LCM fitting over the full complex data versus the real data and how these results might be affected by common spectral preprocessing procedure zero filling. Here, we employ linear combination modeling of simulated and measured spectral data to examine two major ideas: first, whether use of the full complex rather than real-only data can provide improvements in quantification by linear combination modeling and, second, to what extent zero filling might influence these improvements. We examine these questions by evaluating the errors of linear combination model fits in the complex versus real domains against three classes of synthetic data: simulated Lorentzian singlets, simulated metabolite spectra excluding the baseline, and simulated metabolite spectra including measured in vivo baselines. We observed that complex fitting provides consistent improvements in fit accuracy and precision across all three data types. While zero filling obviates the accuracy and precision benefit of complex fitting for Lorentzian singlets and metabolite spectra lacking baselines, it does not necessarily do so for complex spectra including measured in vivo baselines. Overall, performing linear combination modeling in the complex domain can improve metabolite quantification accuracy relative to real fits alone. While this benefit can be similarly achieved via zero filling for some spectra with flat baselines, this is not invariably the case for all baseline types exhibited by measured in vivo data.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/nbm.5236 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!