A two-year clinical trial of enamel wear opposing 5Y-TZP and lithium disilicate crowns.

J Prosthet Dent

Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand. Electronic address:

Published: August 2024

Statement Of Problem: Clinical information on enamel wear opposing 5 mol% yttria-stabilized tetragonal zirconia polycrystal (5Y-TZP) or lithium disilicate crowns is lacking. Moreover, the effect of surface roughness on the wear of enamel antagonists remains unclear.

Purpose: The purpose of this clinical study was to quantify the vertical wear and total volume of wear while also measuring the surface roughness of antagonists at 6-month intervals over 2 years.

Material And Methods: A tooth-supported first molar 5Y-TZP Lava Esthetic Fluorescent Zirconia crown or an IPS e.max CAD lithium disilicate crown was randomly provided for 24 participants (n=12). The contralateral first molar and opposite teeth were the natural enamel controls. The crowns were fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology and then polished. The data were gathered every 6 months at recall appointments with an intraoral scanner and a polyvinyl siloxane impression. A 3-dimensional (3D) comparative software program was used to measure the maximum vertical and volume loss on opposing enamel, as well as on the enamel control on the opposite side of the mouth. The surface of epoxy resin replicas was analyzed using a scanning electron microscope. The surface roughness of the cusp replica was measured with a 3D laser microscope. The crown's antagonist enamel and natural enamel wear were compared using a 2-way repeated measure ANOVA (α=.05).

Results: No significant difference was found in the average volume loss between the crown's antagonist enamel (ZTE 0.042 ±0.005 mm, LTE 0.048 ±0.006 mm) and the enamel control (ZCE 0.046 ±0.004 mm, LCE 0.050 ±0.005 mm) (P>.05). No significant difference was found in surface roughness between the crown's antagonist enamel (antagonist enamel of zirconia group [ZTE] 0.7 ±0.3 µm, antagonist enamel of lithium disilicate group [LTE] 0.6 ±0.3 µm) and the enamel control (enamel control of zirconia group [ZCE] 0.7 ±0.3 µm, enamel control of lithium disilicate group [LCE] 0.5 ±0.2 µm) in both zirconia and lithium disilicate groups (P>.05). Also, no correlation was found between the amount of wear and the roughness of the surface. The wear patterns observed on the opposing enamel surfaces of the monolithic zirconia and lithium disilicate materials were found to be similar to those seen on natural enamel.

Conclusions: A 2-year clinical investigation found that polished lithium disilicate and 5Y-TZP crowns did not affect enamel wear more than enamel against enamel, contrary to laboratory studies. Another finding revealed that surface roughness did not significantly affect wear.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2024.07.009DOI Listing

Publication Analysis

Top Keywords

lithium disilicate
32
enamel
20
surface roughness
20
enamel control
20
antagonist enamel
20
enamel wear
16
crown's antagonist
12
wear
10
wear opposing
8
lithium
8

Similar Publications

Minimally Invasive Glass-Ceramic Restorations: Clinical and Patient-Reported Outcomes in Full-Mouth Rehabilitations.

J Dent

January 2025

Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, CH-8032, Zurich, Switzerland.

Objectives: To evaluate clinical outcomes (restoration survival, technical and biological complications), and patient-reported outcome measures (PROMs) of full mouth rehabilitation with minimally invasive glass-ceramic restorations after up to 12 years of clinical service.

Materials And Methods: Twenty individuals (12 females, 8 males) received full-mouth rehabilitation with minimally invasive tooth-supported glass-ceramic restorations during the years 2009 - 2017 and agreed to participate in a follow-up visit. Full dental and periodontal examinations were completed, and the restorations were evaluated according to United States Public Health Service (USPHS) criteria.

View Article and Find Full Text PDF

Objective: To evaluate the influence of different cleaning methods, surface treatments, and aging on the repair bond strength to a CAD/CAM glass-ceramic.

Materials And Methods: Forty-eight lithium disilicate CAD/CAM ceramic blocks were fabricated, sintered, and embedded in acrylic resin. After contamination with human saliva, they were divided according to the factors "Cleaning method" (Control-water/air spray, Air-particle abrasion with AlO, Ivoclean cleaning paste), "Surface treatment" (5% Hydrofluoric acid-HF + Silane, Monobond Etch & Prime-MEP), and "Aging" (thermocycling, no thermocycling).

View Article and Find Full Text PDF

Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study).

BMC Oral Health

January 2025

Division of Fixed Prosthodontics, Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Background: Increasing demand for durable and aesthetically pleasing dental restorations, including laminates, inlays, onlays, and crowns, has led to advancements in all-ceramic systems, particularly with the development of advanced lithium disilicate materials. However, limited data on the fit accuracy and fracture resistance of these materials restricts their wider application in clinical restorative practices.

Aim Of The Study: This in vitro study aims to compare the marginal and internal fit, assess the fracture resistance, and evaluate the failure modes of crowns fabricated from advanced and conventional lithium disilicate materials.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the chemical solubility (CS) and conduct a comprehensive physicochemical characterization of several experimental and commercial lithium silicate-based glass-ceramics towards an understanding of the chemical processes governing dissolution in these glass-ceramics.

Methodology: Glass-ceramic (GC) samples were categorized into two groups: experimental materials featuring lithium metasilicate crystals (GCE1 and GCE2); and five commercial brands relying mostly on lithium disilicate (Celtra®Duo, IPS e.max®CAD, Straumann®n!ce®, CEREC Tessera™, and VITA Suprinity®).

View Article and Find Full Text PDF

Effect of crystallization and finish line curvature on the marginal integrity of lithium disilicate crowns.

J Prosthodont

January 2025

Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, South Korea.

Purpose: This study aimed to investigate the effect of crystallization and finish line curvature on the integrity of lithium disilicate crowns fabricated by using partially crystallized (P) and fully crystallized (F) blocks.

Materials And Methods: Forty-eight lithium disilicate crowns were fabricated based on the designated lithium disilicate blocks and finish line curvatures. The specimens were divided into four groups (n = 12 each): P block with a curved finish line (PC), P block with a straight finish line (PS), F block with a curved finish line (FC), and F block with a straight finish line (FS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!