Predicting time-of-flight with Cerenkov light in BGO: a three-stage network approach with multiple timing kernels prior.

Phys Med Biol

State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China.

Published: August 2024

In the quest for enhanced image quality in positron emission tomography (PET) reconstruction, the introduction of time-of-flight (TOF) constraints in TOF-PET reconstruction offers superior signal-to-noise ratio. By employing BGO detectors capable of simultaneously emitting prompt Cerenkov light and scintillation light, this approach combines the high time resolution of prompt photons with the high energy resolution of scintillation light, thereby presenting a promising avenue for acquiring more precise TOF information.In Stage One, we train a raw method capable of predicting TOF information based on coincidence waveform pairs. In Stage Two, the data is categorized into 25 classes based on signal rise time, and the pre-trained raw method is utilized to obtain TOF kernels for each of the 25 classes, thereby generating prior knowledge. Within Stage Three, our proposed deep learning (DL) module, combined with a bias fine-tuning module, utilizes the kernel prior to provide bias compensation values for the data, thereby refining the first-stage outputs and obtaining more accurate TOF predictions.The three-stage network built upon the LED method resulted in improvements of 11.7 ps and 41.8 ps for full width at half maximum (FWHM) and full width at tenth maximum (FWTM), respectively. Optimal performance was achieved with FWHM of 128.2 ps and FWTM of 286.6 ps when CNN and Transformer were utilized in Stages One and Three, respectively. Further enhancements of 2.3 ps and 3.5 ps for FWHM and FWTM were attained through data augmentation methods.This study employs neural networks to compensate for the timing delays in mixed (Cerenkov and scintillation photons) signals, combining multiple timing kernels as prior knowledge with DL models. This integration yields optimal predictive performance, offering a superior solution for TOF-PET research utilizing Cerenkov signals.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad6ed8DOI Listing

Publication Analysis

Top Keywords

cerenkov light
8
three-stage network
8
multiple timing
8
timing kernels
8
kernels prior
8
scintillation light
8
raw method
8
prior knowledge
8
full width
8
tof
5

Similar Publications

Synergistic Nonreciprocity of Linear and Nonlinear Optical Diffraction.

Phys Rev Lett

November 2024

School of Physics and Optoelectronics, South China University of Technology, Guangzhou 510641, China.

Linear optical diffraction of light is a basic natural phenomenon subject to a long history study and it obeys the well-known reciprocity in transport. In this work we report observation of synergistic nonreciprocal linear and nonlinear diffraction of a Ti:sapphire femtosecond laser beam against a periodic poled lithium niobate (PPLN) thin plate nonlinear grating with a front surface corrugated with a shallow grating of a depth only 67 nm and a smooth back surface. A high peak power pump laser beam shining upon the geometrically asymmetric nonlinear grating from either the front surface and back surface will both cause significant second-order nonlinear (2nd-NL) Raman-Nath diffraction and Cerenkov radiation, in addition to apparent linear optical diffraction and modest third-order nonlinear (3rd-NL) spectral broadening.

View Article and Find Full Text PDF

Ag phantom images with Cerenkov Luminescence Imaging and digital autoradiography within the ISOLPHARM project.

Appl Radiat Isot

January 2025

Legnaro National Laboratories, National Institute for Nuclear Physics, INFN-LNL, Viale dell'Università 2, 35020 Legnaro, Italy. Electronic address:

Targeted Radionuclide Therapy (TRT) is a medical technique exploiting radionuclides to combat cancer growth and spread. TRT requires a supply of radionuclides that are currently produced by either cyclotrons or nuclear research reactors. In this context, the ISOLPHARM project investigates the production of innovative radionuclides for medical applications.

View Article and Find Full Text PDF

Self-Illuminating In Situ Hydrogel with Immune-Adjuvant Amplify Cerenkov Radiation-Induced Photodynamic Therapy.

Chem Biomed Imaging

April 2024

State Key Laboratory of Natural Medicines, Key Laboratory of Drug Quality Control and Pharmacovigilance, School of Pharmacy, China Pharmaceutical University, Nanjing 210009, China.

Cerenkov radiation-induced photodynamic therapy (CR-induced PDT) has shown the potential to overcome the light penetration limitation in conventional PDT. In addition, the tumor-associated antigens (TAAs) produced by PDT can initiate an antitumor immune process but only show a limited immunotherapeutic effect without the use of immunotherapeutic agents. Herein, a CR-induced PDT hydrogel (R837/Zr-HG-PpIX) has been developed by in situ formation of a hyaluronic acid (HA)-based hydrogel integrated with internal light source Zr, photosensitizer protoporphyrin IX (PpIX), and immune adjuvant imiquimod (R837).

View Article and Find Full Text PDF

Evaluation of TOPAS MC tool performance in optical photon transport and radioluminescence-based dosimetry.

Biomed Phys Eng Express

August 2024

Fiber Optics Research Centre, Faculty of Engineering, Multimedia University, Jalan Multimedia, 63100, Cyberjaya, Malaysia.

Radiation therapy plays a pivotal role in modern cancer treatment, demanding precise and accurate dose delivery to tumor sites while minimizing harm to surrounding healthy tissues. Monte Carlo simulations have emerged as indispensable tools for achieving this precision, offering detailed insights into radiation transport and interaction at the subatomic level. As the use of scintillation and luminescence dosimetry becomes increasingly prevalent in radiation therapy, there arises a need for validated Monte Carlo tools tailored to optical photon transport applications.

View Article and Find Full Text PDF

Predicting time-of-flight with Cerenkov light in BGO: a three-stage network approach with multiple timing kernels prior.

Phys Med Biol

August 2024

State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China.

In the quest for enhanced image quality in positron emission tomography (PET) reconstruction, the introduction of time-of-flight (TOF) constraints in TOF-PET reconstruction offers superior signal-to-noise ratio. By employing BGO detectors capable of simultaneously emitting prompt Cerenkov light and scintillation light, this approach combines the high time resolution of prompt photons with the high energy resolution of scintillation light, thereby presenting a promising avenue for acquiring more precise TOF information.In Stage One, we train a raw method capable of predicting TOF information based on coincidence waveform pairs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?