Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The deposition of inhaled medications is the first step in the pulmonary pharmacokinetic process to produce a therapeutic response. Not only lung dose but more importantly the distribution of deposited drug in the different regions of the lung determines local bioavailability, efficacy, and clinical safety. Assessing aerosol deposition patterns has been the focus of intense research that combines the fields of physics, radiology, physiology, and biology.
Areas Covered: The review covers the physics of aerosol transport in the lung, experimental, and in-silico modeling approaches to determine lung dose and aerosol deposition patterns, the effect of asthma, chronic obstructive pulmonary disease, and cystic fibrosis on aerosol deposition, and the clinical translation potential of determining aerosol deposition dose.
Expert Opinion: Recent advances in in-silico modeling and lung imaging have enabled the development of realistic subject-specific aerosol deposition models, albeit mainly in health. Accurate modeling of lung disease still requires additional refinements in existing imaging and modeling approaches to better characterize disease heterogeneity in peripheral airways. Nevertheless, recent patient-centric innovation in inhaler device engineering and the incorporation of digital technology have led to more consistent lung deposition and improved targeting of the distal airways, which better serve the clinical needs of patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11412782 | PMC |
http://dx.doi.org/10.1080/17425247.2024.2392790 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!