Purpose: To assess the survival and complication rates of 115 monolithic zirconia implant-supported fixed complete dental prostheses (IFCDPs) with an up to 6-year follow-up.

Materials And Methods: One hundred fifteen edentulous jaws (71 patients) underwent complete-arch implant treatment with a digital workflow and were rehabilitated with monolithic zirconia IFCDPs. The primary outcome was to assess survival and complication rates while the secondary outcome was to measure the cross-sectional dimensions (prosthetic space) of those 115 monolithic zirconia IFCDPs and to correlate potential technical complications with the prosthetic space dimensions.

Results: Out of the 115 zirconia IFCDPs, 2 fractured, yielding a 98.6% survival rate up to a 6-year follow-up. The most commom minor technical complications were loss of screw access channel filling and porcelain chipping for the modified monolithic IFCDPs. There was no significant association between the count and type of complications and jaw location (maxilla vs. mandible) or prosthesis type (FP1 vs. FP3), according to Fisher's exact test. For maxillary zirconia IFCDPs, the mean square surface for the at the posterior abutment cross-sectional area was 25.18 mm at the lingual side of the abutment and 34.19 mm at the buccal side, respectively. The anterior abutment cross-sectional area was 33.92 mm at the lingual side of the abutment and 29.49 mm at the buccal side, respectively. For mandibular zirconia IFCDPs, the mean square surface at the posterior abutment cross-sectional area was 29.89 mm at the lingual side of the abutment and 39.05 mm at the buccal side, respectively. The anterior abutment cross-sectional area was 27.07 mm at the lingual side of the abutment and 56.50 mm at the buccal side, respectively. At the connector cross-sectional area, the mean square surface for the maxillary zirconia IFCDPs was 64.33 and 90.56 mm for the mandibular zirconia IFCDPs. The two fractures occurred in the midline (anterior area) for both maxillary FP1 prosthesis and mandibular FP3 prosthesis. The mean surface area at the connector for the maxillary FP1 prosthesis was 28.50 and 82.11 mm for the mandibular FP3 prosthesis, and was within the range of IFCDP connector square surface area. There was no significant association between the thickness of the zirconia prosthesis and the encountered prosthesis fractures.

Conclusions: Monolithic zirconia IFCDPs yielded a 98.6% survival rate, after a mean observation period of 62 months with an SE of 3.1. The connector mean surface area in the two fractured IFCDPs was within the square surface range (minimum-maximum) as for the remaining 113 complication-free IFCDPs.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.13922DOI Listing

Publication Analysis

Top Keywords

zirconia ifcdps
32
square surface
20
cross-sectional area
20
monolithic zirconia
16
abutment cross-sectional
16
lingual side
16
side abutment
16
buccal side
16
prosthetic space
12
ifcdps
12

Similar Publications

Design: A retrospective cohort study assessing the mid-to-long-term outcomes and risk factors affecting the prosthetic success and survival of implant-supported cross-arch fixed dental prostheses (IFCDPs) with monolithic zirconia frameworks.

Cohort Selection: Forty-seven patients received a total of 51 cross-arch prostheses (27 maxillary and 24 mandibular prostheses), supported by 302 implants. Comprehensive clinical and radiographic records were available over a follow-up period ranging from 5 to 13 years.

View Article and Find Full Text PDF

Purpose: To investigate the mid-to-long term clinical outcomes of the implant-supported cross-arch fixed dental prostheses (IFCDPs) with monolithic zirconia-based frameworks and related risk factors of success and survival.

Materials And Methods: This retrospective study encompassed individuals exhibiting terminal dentition or edentulism in the maxilla and/or mandible who underwent treatment involving IFCDPs with monolithic zirconia frameworks. Inclusion criteria required a documented follow-up period of at least five years post-definitive prosthesis delivery.

View Article and Find Full Text PDF

This clinical report introduces a digital approach that utilizes milled verification jigs to acquire the jaw relations for the fabrication of monolithic zirconia implant-supported fixed complete dental prosthesis (IFCDP), in patients without a conversion implant prosthesis. The procedures employ photogrammetry for precise data acquisition, combined with image-based capture in 4 dimensions (ICAM4D), to design and mill verification jigs that accurately record the occlusal vertical dimension (OVD) and centric relation (CR). This approach streamlines the clinical workflow by reducing the number of patient visits and associated costs while enhancing precision and predictability.

View Article and Find Full Text PDF

Purpose: To assess the survival and complication rates of 115 monolithic zirconia implant-supported fixed complete dental prostheses (IFCDPs) with an up to 6-year follow-up.

Materials And Methods: One hundred fifteen edentulous jaws (71 patients) underwent complete-arch implant treatment with a digital workflow and were rehabilitated with monolithic zirconia IFCDPs. The primary outcome was to assess survival and complication rates while the secondary outcome was to measure the cross-sectional dimensions (prosthetic space) of those 115 monolithic zirconia IFCDPs and to correlate potential technical complications with the prosthetic space dimensions.

View Article and Find Full Text PDF

Purpose: To evaluate the relationship between different dimensional parameters in implant-supported monolithic zirconia fixed complete dental prostheses (IFCDPs) and the incidence of framework fracture in a large sample of cases in vivo.

Materials And Methods: This retrospective observational study evaluated all patients rehabilitated with screw-retained zirconia IFCDPs between January 2013 and April 2019 at a private practice. The minimum follow-up period was 1 year after occlusal loading.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!