Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11308625PMC
http://dx.doi.org/10.1016/j.jscai.2024.102144DOI Listing

Publication Analysis

Top Keywords

novel microcatheter
4
microcatheter enters
4
enters chronic
4
chronic total
4
total occlusion
4
occlusion space
4
space advancement
4
advancement device?
4
novel
1
enters
1

Similar Publications

Background And Purpose: Mechanical thrombectomy (MT) has become the standard of care for treatment of acute ischemic stroke secondary to large vessel occlusion up to 24 h from the last known normal time. With ADAPT and SOLUMBRA techniques, classically, a large bore aspiration catheter is delivered over a microcatheter and microwire crossing the clot to perform thrombectomy. Recently, a novel macrowire (Colossus 035 in.

View Article and Find Full Text PDF

Sublober resection of small peripheral lung lesions using video-assisted thoracoscopic surgery may require marking and confirmation using 3D imaging in the interventional radiology suite or in the hybrid operating room (HOR) before surgery is started. We report a novel approach for intraoperative transbronchial metallic coil marking followed by thoracoscopic wedge resection in a conventional operating room under mobile 3D C-arm guidance. Under general anesthesia, an ultrathin video-bronchoscope was inserted into an objective bronchus guided with virtual bronchoscopic navigation, and a coil-feeding microcatheter was introduced through the bronchoscope's channel.

View Article and Find Full Text PDF
Article Synopsis
  • Researchers developed a new rat model of thromboembolic stroke to achieve consistent infarct sizes and locations within the middle cerebral artery (MCA) without needing arterial ligation.
  • The model involved using a microcatheter to place a zirconium dioxide blood clot in the artery, and monitoring was done through fluoroscopy over 24 hours.
  • The results showed that the blood clot position remained stable in most rats, with a median infarct volume of 242 mm, highlighting the model's potential for testing new stroke treatments.
View Article and Find Full Text PDF
Article Synopsis
  • - Hemorrhage is the main cause of preventable death in trauma situations, leading to military and civilian advancements in medical practices, particularly through the use of tourniquets to manage extremity bleeding and save lives.
  • - While tourniquets have significantly decreased deaths from bleeding in military settings, noncompressible hemorrhage still poses a major risk, especially before patients receive definitive medical care.
  • - The study explores using a small, disposable pressure monitor during resuscitative endovascular balloon occlusion of the aorta (REBOA) to enhance blood pressure monitoring, facilitate better resuscitation practices, and reduce the need for blood products in extreme environments.
View Article and Find Full Text PDF

Background: The reverse-wiring technique (RWT) using a hairpin-bend wire is useful for percutaneous coronary intervention of a bifurcation lesion with an extremely angulated side branch (SB); however, it is not necessarily effective in some anatomical situations. We report a novel SB wiring technique, the U-turn wiring technique (UWT), that is useful for wiring an extremely angled SB proximal to the ectasia.

Case Summary: In the first case, the bare wire took a U-turn in the ectasia of the diagonal branch and crossed towards the angled left anterior descending artery, but a coronary dissection occurred in the diagonal branch due to the continuous wire-pushing force.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!