In this study, we examine the electrochemical performance of supercapacitor (SC) electrodes made from 3D-printed nanocomposites. These composites consist of multiwalled carbon nanotubes (MWCNTs) and polyether ether ketone (PEEK), coated with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). The electrochemical performance of a 3D-printed PEEK/MWCNT solid electrode with a surface area density of 1.2 mm is compared to two distinct periodically porous PEEK/MWCNT electrodes with surface area densities of 7.3 and 7.1 mm. To enhance SC performance, the 3D-printed electrodes are coated with a conductive polymer, PEDOT:PSS. The architected cellular electrodes exhibit significantly improved capacitive properties, with the cellular electrode (7.1 mm) displaying a capacitance nearly four times greater than that of the solid 3D-printed electrode-based SCs. Moreover, the PEDOT:PSS-coated cellular electrode (7.1 mm) demonstrates a high specific capacitance of 12.55 mF·cm at 50 mV·s, contrasting to SCs based on 3D-printed cellular electrodes (4.09 mF·cm at 50 mV·s) without the coating. The conductive PEDOT:PSS coating proves effective in reducing surface resistance, resulting in a decreased voltage drop during the SCs' charging and discharging processes. Ultimately, the 3D-printed cellular nanocomposite electrode with the conductive polymer coating achieves an energy density of 1.98 μW h·cm at a current of 70 μA. This study underscores how the combined effect of the surface area density of porous electrodes enabled by 3D printing, along with the conductivity imparted by the polymer coating, synergistically improves the energy storage performance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11307982 | PMC |
http://dx.doi.org/10.1021/acsomega.4c04576 | DOI Listing |
Biosens Bioelectron
January 2025
Centre for Advanced Optoelectronic Functional Materials Research and Key Laboratory of UV Light-Emitting Materials and Technology of Ministry of Education, Northeast Normal University, 130024, Changchun, China. Electronic address:
The development of integrated multiple signal outputs within a single platform is highly significant for efficient and accurate on-site biomarker detection. Herein, colorimetric/electrochemical dual-mode microfluidic paper-based analytical devices (μPADs) were designed for portable, visual and accurate dopamine (DA) detection. The dual-mode μPADs, featuring folded structure, integrate a colorimetric layer and an electrochemical layer using wax printing and laser-induced graphene (LIG) pyrolysis techniques, allowing the vertical flow of analyte solution.
View Article and Find Full Text PDFEnviron Sci Technol
January 2025
Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China.
Electrochemical oxidation via in situ-generated reactive oxygen species (ROS) is effective for the mineralization of refractory organic pollutants. However, the oxidation performance is usually limited by the low yield and utilization efficiency of ROS. Herein, a B/N-doped diamond (BND) flow-through electrode with enhanced SO/OH generation and utilization was designed for electrochemical oxidation of organic pollutants in sulfate solution.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States.
Electrochemical aptamer-based (EAB) sensors are a molecular measurement platform that enables the continuous, real-time measurement of a wide range of drugs and biomarkers in situ in the living body. EAB sensors are fabricated by depositing a thiol-modified, target-binding aptamer on the surface of a gold electrode, followed by backfilling with an alkanethiol to form a self-assembled monolayer. And while the majority of previously described EAB sensors have employed hydroxyl-terminated monolayers, a handful of studies have shown that altering the monolayer headgroup can strongly affect sensor performance.
View Article and Find Full Text PDFLangmuir
January 2025
School of Environment and Architecture, University of Shanghai for Science and Technology, Shanghai 200093, China.
Herein, first, MIL-125 samples were synthesized via a hydrothermal method. Then, Ag species were doping on the surface of MIL-125 samples via the photolysis of silver nitrate. Finally, the Z-scheme MIL-125/Ag/BiOBr composite was synthesized via a directed liquid assembly method.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
International Science and Technology Cooperation Base of Energy Materials and Application, College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, P.R. China.
Poly(ethylene oxide) (PEO) has been widely studied as an electrolyte owing to its excellent lithium compatibility and good film-forming properties. However, its electrochemical performance at room temperature remains a significant challenge due to its low ionic conductivity, narrow electrochemical window, and continuous decomposition. Herein, we prepare a multifunctional polar polymer to optimize PEO's electrochemical properties and cycling stability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!