A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of the AViTA upper-arm blood pressure monitor BP636 with multiple cuff sizes in the general population according to the ANSI/AAMI/ISO 81060-2:2018/Amd1:2020. | LitMetric

Objective: To determine the accuracy of the AViTA BP636 upper-arm home blood pressure (BP) monitor in general populations with small to extra-large arms according to the ANSI/AAMI/ISO Universal Standard (ISO 81060-2 : 2018/Amd1 : 2020).

Methods: The AViTA BPM636 was utilized on 85 adult participants with upper-arm circumferences ranging from 15 to 52 cm, and four cuffs of different sizes (small: 15-22 cm, normal: 22-33 cm, large: 33-42 cm, and extra large: 42-52 cm) were used in this study. The recruitment fulfills the criteria of the ANSI/AAMI/ISO Universal Standard 81060-2 : 2018/Amd1 : 2020 in the general population using the same arm sequential BP measurement method.

Results: For validation criterion 1, the mean ± SD of the differences between the test device and reference blood pressure readings was -0.35 ± 4.68/0.56 ± 3.93 mmHg (systolic/diastolic) for adults. The mean difference of SBP between the test device and the reference device was -0.35 mmHg with a SD of 3.50 mmHg, which was within the acceptable range for criterion 2 (i.e. less than 6.93 mmHg) Similarly, the mean difference in DBP was 0.56 mmHg with a SD of 3.38 mmHg, which also met the criterion 2 (i.e. within 6.91 mmHg).

Conclusion: AViTA BPM636 passed the criteria of the ANSI/AAMI/ISO 81060-2 : 2018/Amd 1 : 2020 protocol. It can be recommended for home-based BP measurements in the general population and people with extra-large arms ranging from 42 to 52 cm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11524622PMC
http://dx.doi.org/10.1097/MBP.0000000000000722DOI Listing

Publication Analysis

Top Keywords

blood pressure
12
general population
12
upper-arm blood
8
pressure monitor
8
extra-large arms
8
ansi/aami/iso universal
8
universal standard
8
avita bpm636
8
ranging 52 cm
8
criteria ansi/aami/iso
8