Peanut allergy has garnered worldwide attention due to its high incidence rate and severe symptoms, stimulating the demand for the ultrasensitive detection method of peanut allergen. Herein, we successfully developed a novel electrochemical aptasensor for ultrasensitive detection Ara h1, a major allergenic protein present in peanuts. A conductive nickel atoms Anchored Hydrogen-Bonded Organic Frameworks (PFC-73-Ni) were utilized as excellent electrocatalysts toward hydroquinone (HQ) oxidation to generate a readable current signal. The developed electrochemical aptasensor offers wide linear range (1-120 nM) and low detection limit (0.26 nM) for Ara h1. This method demonstrated a recovery rate ranging from 95.00% to 107.42% in standard addition detection of non-peanut food samples. Additionally, the developed electrochemical method was validated with actual samples and demonstrated good consistency with the results obtained from a commercial ELISA kit. This indicates that the established Ara h1 detection method is a promising tool for peanut allergy prevention.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.foodchem.2024.140777 | DOI Listing |
R Soc Open Sci
January 2025
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo 11562, Egypt.
Carbon quantum dots (CQDs) are a recently developed class of fluorescent nanoparticles made from carbon. Co-doping with heteroatoms such as nitrogen and sulfur improved the properties and generated a high quantum yield. In the proposed study, we utilized a simple, cost-effective, single-stage hydrothermal approach to produce extreme photoluminescence co-doped, nitrogen and sulfur, CQDs (N,S-CODs).
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
January 2025
Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Bio-functional Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, Jiangsu, PR China. Electronic address:
Metal aluminum ions and the antibiotic NOR have both benefited humanity and due to improper use, posed significant threats to the environment and human health. Although the correct and rational use of these substances is crucial, developing real-time, rapid, and highly sensitive detection of trace aluminum ions and NOR in the environment and organisms is more important for early diagnosis of potential related diseases. After several decades of development, fluorescence analysis has become a mainstream research method due to its ability to meet these requirements.
View Article and Find Full Text PDFBiosens Bioelectron
January 2025
Department of Electronic, Electrical and Systems Engineering, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK; School of Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, UK; School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia. Electronic address:
Closed-channel microfluidic systems offer versatile on-chip capabilities for bioanalysis but often face complex fabrication and operational challenges. In contrast, free-boundary off-chip microfluidic platforms are relatively simple to fabricate and operate but lack the ability to perform complex tasks such as on-demand single-target sorting and encapsulation. To address these challenges, we develop an off-chip platform powered by a fluorescent-activated mechanical droplet sorting and production (FAM-DSP) system.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
January 2025
University of Pittsburgh School of Medicine, Structural Biology, 3501 5th Ave., Biomedical Science Tower 3, Room 2044, 15261, Pittsburgh, UNITED STATES OF AMERICA.
Bacterial biofilms are major contributors to persistent infections and antimicrobial resistance, posing significant challenges to treatment. However, obtaining high-resolution structural information on native bacterial biofilms has remained elusive due to the methodological limitations associated with analyzing complex biological samples. Solid-state NMR (ssNMR) has shown promise in this regard, but its conventional application is hindered by sensitivity constraints for unlabeled native samples .
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Changning Road 865, Shanghai, 200050, China.
Chemo-sensor designing involves a time-consuming trial-and-error screening process, which commonly cannot lead to optimal SR features (Sensitivity, Selectivity, Speed, Stability, and Reversibility). Due to strong path dependence on reported groups/mechanisms, conventional chemo-sensors often fail to meet critical application demands, especially in achieving high reversibility without compromising other features. Here, a three-step screen and design strategy is developed for gaining customized chemo-sensors, through Structure modeling; MEMS (Micro Electro Mechanical Systems) analysis, and Performance verification.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!