Within the realm of pharmacological strategies for cardiovascular diseases (CVD) like hypertension, stroke, and heart failure, targeting the angiotensin-converting enzyme I (ACE-I) stands out as a significant treatment approach. This study employs QSAR modeling using Monte Carlo optimization techniques to investigate a range of compounds known for their ACE-I inhibiting properties. The modeling process involved leveraging local molecular graph invariants and SMILES notation as descriptors to develop conformation-independent QSAR models. The dataset was segmented into distinct sets for training, calibration, and testing to ensure model accuracy. Through the application of various statistical analyses, the efficacy, reliability, and predictive capability of the models were evaluated, showcasing promising outcomes. Additionally, molecular fragments derived from SMILES notation descriptors were identified to elucidate the activity changes observed in the compounds. The validation of the QSAR model and designed inhibitors was carried out via molecular docking, aligning well with the QSAR results. To ascertain the drug-worthiness of the designed molecules, their physicochemical properties were computed, aiding in the prediction of ADME parameters, pharmacokinetic attributes, drug-likeness, and medicinal chemistry compatibility.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiolchem.2024.108167DOI Listing

Publication Analysis

Top Keywords

monte carlo
8
carlo optimization
8
qsar modeling
8
molecular docking
8
smiles notation
8
notation descriptors
8
qsar
5
silico development
4
development novel
4
novel angiotensin-converting-enzyme-i
4

Similar Publications

The natural environment and public health are gravely threatened by the enrichment of soil potentially toxic elements (PTEs). To explore the contamination level, sources and human health risks posed by PTEs, high-density soil sampling was carried out in the upper Wei River region (UWRR). The results demonstrated that the pollution risk and ecological risk in UWRR as a whole were at a low level, but there were moderate or higher ecological risks of Hg and Cd in some areas.

View Article and Find Full Text PDF

The three-dimensional radiation field is an important database reflecting the radioactivity distribution in a nuclear facility. It is of great significance to accurately and quickly grasp the radiation dose field distribution to implement radiation protection. Presently, majority of radiation field reconstruction algorithms concentrate on two-dimensional reconstruction and can only measure on a regular grid.

View Article and Find Full Text PDF

Notable ecological risks of microplastics to Minjiang River ecosystem over headwater to upstream in Eastern Qinghai-Tibetan Plateau.

Water Res

January 2025

CAS Key Laboratory of Mountain Ecological Restoration and Bio-resources Utilization, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, China. Electronic address:

Microplastics (MPs) in aquatic environments has been observed globally. However, the ecological risks of MP pollution in riverhead prior to highly urbanized region remain poorly understood. This study investigated MP pollution related to microbiome in sediments, and ecological risks of MPs in riverhead prior to urbanized area over 291 km of Minjiang River (MJR) in Qinghai-Tibetan Plateau (QTP).

View Article and Find Full Text PDF

CoReSi: a GPU-based software for Compton camera reconstruction and simulation in collimator-free SPECT.

Phys Med Biol

January 2025

CREATIS, INSA de Lyon, Bâtiment Blaise Pascal, 7 Avenue Jean Capelle, Villeurbanne, 69621 Cedex , FRANCE.

Compton cameras are imaging devices that may improve observation of sources of γ photons. We present CoReSi, a Compton Reconstruction and Simulation software implemented in Python and powered by PyTorch to leverage multi-threading and for easy interfacing with image processing and deep learning algorithms. The code is mainly dedicated to medical imaging and for near-field experiments where the images are reconstructed in 3D.

View Article and Find Full Text PDF

The increasing interest in hadron therapy has heightened the need for accurate and reliable methods to assess radiation quality and the biological effectiveness of particles used in treatment. Microdosimetry has emerged as a key tool for this, demonstrating its potential, reliability, and suitability. In this context, solid-state microdosimeters offer technological advantages over traditional Tissue-Equivalent Proportional Counters, and recent advancements have further improved their performance and reliability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!